Microfluidics: Sorting particles with light.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jesper Glückstad. 2004. Microfluidics: Sorting particles with light.. https://doi.org/10.1038/nmat1041

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prototype heel effect compensation filter for cone-beam CT.

The prototype cone-beam CT (CBCT) has a larger beam width than the conventional multi-detector row CT (MDCT). This causes a non-uniform angular distribution of the x-ray beam intensity known as the heel effect. Scan conditions for CBCT tube current are adjusted on the anode side to obtain an acceptable clinical image quality. However, as the dose is greater on the cathode side than on the anode side, the signal-to-noise ratio on the cathode side is excessively high, resulting in an unnecessary dose amount. To compensate for the heel effect, we developed a heel effect compensation (HEC) filter. The HEC filter rendered the dose distribution uniform and reduced the dose by an average of 25% for free air and by 20% for CTDI phantoms compared to doses with the conventional filter. In addition, its effect in rendering the effective energy uniform resulted in an improvement in image quality. This new HEC filter may be useful in cone-beam CT studies.

Equipment Design↗

The design and characteristic features of a new time-of-flight mass spectrometer with a spiral ion trajectory.

A new time-of-flight (TOF) mass spectrometer with a corkscrew ion trajectory was designed and constructed. The spiral trajectory was realized by using four toroidal electrostatic sectors. Each had fifteen-stories made of sixteen Matsuda plates piled up inside a cylindrical electrostatic sector. The ions passed the four toroidal electrostatic sectors sequentially and revolved along a figure-eight-shaped orbit on a certain projection plane. During the multiple revolutions, each ion trajectory was shifted by 50 mm per cycle on a direction perpendicular to the projection plane, thus generating a spiral trajectory. The flight path length of one cycle was 1.308 m so that the maximum flight path length became approximately 20 m. The mass resolution, mass accuracy, and ion transmission were tested by utilizing an orthogonally coupled electron ionization source. A mass resolution of 35,000 (FWHM) for m/z greater than 300 was achieved. Even in a lower mass region, mass resolutions of more than 20,000 (FWHM) were confirmed with a doublet of (12)C(5)(1)H(5)(14)N(+) and (13)C(12)C(5)(1)H(6)(+). The mass accuracy was also improved such that it was better than 1 ppm with only one internal standard peak. An ion transmission of approximately of 100% was observed for 15 cycles.

Equipment Design↗