PubMed Health⌕ Search

PubMed · 14709223

Laser-induced temperature changes in dentine.

Abstract

OBJECTIVE: The purpose of this work is to study the temperature rise and potential thermal damage caused during ablation of human dentine using a super pulsed carbon dioxide laser of 9.6-microm wavelength, equipped with a water-cooling spray and scanner system. BACKGROUND DATA: There have been no reports on thermal effects of super pulsed CO2 laser of 9.6 microm wavelength on human dentine recently. MATERIALS AND METHODS: Two different types of samples were investigated to yield data most consistent with a typical clinical situation. Human dentine slices and crown segments were studied at a drilling depth of 1.0 +/- 0.1 mm and 2.5 +/- 0.5 mm, respectively. A control group treated with a conventional hand piece was compared to four laser groups with settings varying from 2 to 8 W. RESULTS: In the laser group demonstrating the highest elevation in temperature of the four studied, dentine slices lased at 2 W for 15 sec showed a mean temperature rise of less than 1.68 degrees C at an ablation rate of 0.86 +/- 0.08 mm. Conventional drilling with a comparable ablation rate of 0.76 +/- 0.59 mm resulted in a mean rise of 2.87 degrees C. The laser groups of crown segments revealed a constant decrease in temperature. SEM observations were lacking the typical morphological changes seen in earlier studies, specifically extensive melting, charring or cracking. CONCLUSION: A maximum rise of mean temperature to 1.68 degrees C in closest vicinity to the pulpal chamber and the morphological unaltered dentine surfaces demonstrate the safe and tissue preserving character of the superpulsed 9.6 microm CO2 laser. The laser caused an even lower temperature rise than conventional drilling. Moreover, the laser showed acceptable efficacy with ablation rates that did not significantly differ from the conventional dental drill.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O R Keller, F E Weber, K W Grätz, M M Baltensperger, G K Eyrich. 2003. Laser-induced temperature changes in dentine.. https://doi.org/10.1089/104454703322650194

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thermographic assessment of inferior alveolar nerve injury in patients with dentofacial deformity.

PURPOSE: The purpose of this study was to evaluate the injury and recovery of the inferior alveolar nerve in orthognathic patients at 1 and 4 weeks after surgery using electronic thermography. MATERIALS AND METHODS: Twenty subjects with Class III dentofacial deformity were studied. All patients underwent bilateral sagittal split ramus osteotomy. To image the temperature of the face, 1 anteroposterior view and 1 lateral view were taken from both the right and left sides. Similar images were taken at 1 and 4 weeks after surgery. The control was the presurgical temperature of the 20 patients who showed unilateral or bilateral nerve damage after surgery. RESULTS: In the patients with unilateral nerve damage (n = 14), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.64 degrees C at 1 week after surgery, and the difference decreased to 0.23 degrees C at 4 weeks after surgery. On the lateral images, the differences in temperature between the mentum areas were 0.10 degrees C at 1 week and 0.27 degrees C at 4 weeks after surgery. In the patients with bilateral nerve injury (n = 6), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.20 degrees C at 1 week after surgery and 0.13 degrees C after 4 weeks. On the lateral views, the differences were 0.18 degrees C at 1 week and 0.34 degrees C at 4 weeks after surgery. Using the repeated measurement analysis method, the anteroposterior view showed statistically significant results in the patients with unilateral nerve damage. CONCLUSION: The infrared body temperature method is an objective method that can be applied as a supplemental diagnostic method for inferior alveolar nerve injury.

Body Temperature↗

The ingestible telemetric body core temperature sensor: a review of validity and exercise applications.

An ingestible telemetric temperature sensor for measuring body core temperature (Tc) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman's limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (Tintestinal), oesophageal temperature (Toesophageal) and rectal temperature (Trectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between Tintestinal and Toesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1 degrees C and 95% LoA within +/-0.4 degrees C). The agreement between Tintestinal and Trectal shows a significant systematic bias >0.1 degrees C, although the 95% LoA is acceptable. Tintestinal responds less rapidly than Toesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than Trectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of Tc in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of Tc and shows excellent utility for ambulatory field-based applications.

Body Temperature↗