PubMed Health⌕ Search

PubMed · 14709638

Beta-thalassemia microelectronic chip: a fast and accurate method for mutation detection.

Abstract

BACKGROUND: beta-Thalassemia is one of the most common genetic diseases in humans. We developed an automated electronic microchip for fast and reliable detection of the nine most frequent mutations accounting for >95% of the beta-thalassemia alleles in the Mediterranean area. METHODS: We developed a microchip-based assay to identify the nine most frequent mutations (cd39C>T, IVS1-110G>A, IVS1-1G>A, IVS1-6T>C, IVS2-745C>G, cd6delA, -87C>G, IVS2-1G>A, and cd8delAA) by use of the Nanogen Workstation. The biotinylated amplicon was electronically addressed on the chip to selected pads, where it remained embedded through interaction with streptavidin in the permeation layer. The DNA at each test site was then hybridized to a mixture of fluorescently labeled wild-type or mutant probes. RESULTS: Assays conditions were established based on the analysis of 700 DNA samples from compound heterozygotes or homozygotes for the nine mutations. The assays were blindly validated on 250 DNA samples previously genotyped by other methods, with complete concordance of results. Alternative multiplexed formats were explored: the combination of multiplex PCR with multiple addressing and/or hybridization allowed analysis of all nine mutations in the same sample on one test site of the chip. CONCLUSIONS: The open flexible platform can be designed by the user according to the local prevalence of mutations in each geographic area and can be rapidly extended to include the remaining mutations causing beta-thalassemia in other regions of the world.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Barbara Foglieni, Laura Cremonesi, Maurizio Travi, Anna Ravani, Antonino Giambona, Maria Cristina Rosatelli, Chiara Perra, Paolo Fortina, Maurizio Ferrari. 2004. Beta-thalassemia microelectronic chip: a fast and accurate method for mutation detection.. https://doi.org/10.1373/clinchem.2003.023077

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conformationally gated photoinduced processes within photosensitizer-acceptor dyads based on osmium(II) complexes with triarylpyridinio-functionalized terpyridyl ligands: insights from theoretical analysis.

A theoretical analysis, based on density functional theory, has been carried out to study photoinduced processes within a recently experimentally characterized (Lainé, P. P.; Bedioui, F.; Loiseau, F.; Chiorboli, C.; Campagna, S. J. Am. Chem. Soc. 2006, http://dx.doi.org/10.1021/ja058357w.) series of Os(II) bis-tpy complexes (tpy = 2,2':6'2' '-terpyridine) functionalized by 2,4,6-triarylpyridinium groups, TP+. These dyad systems, designed to produce a charge-separated state (CSS) upon light excitation, are made up of a photosensitizer unit (P, the metal complex) and a tunable acceptor unit (A, the TP+). A full ab initio characterization of the electronic and structural properties of the lowest-lying triplet excited states, as well as of the CSS, allowed for a complete rationalization of the photoinduced processes taking place within the dyads. Among salient insights, theory allowed (i) substantiation of the inner P structural planarization as the relaxation mode of the MLCT states, (ii) confirmation of the existence of a ligand-centered triplet excited state (3LC) shown to essentially involve the nitro substituent of A (TP+-NO2) and lying very close in energy to the P-centered 3MLCT state, and (iii) a demonstration that the energy of the 3LC level is independent of intercomponent tilt angle (theta1). On this basis, the occurrence of a reversible electronic energy transfer between the 3MLCT and the 3LC states could be substantiated and shown to depend on the intramolecular conformation represented by theta1, which actually governs their electronic coupling (essentially via the degree of intercomponent conjugation). These computational issues were checked against experimental data already available and the results of a specifically undertaken photophysical study. Finally, CSS formation has been confirmed by studying the spin density patterns of reduced nitro-derivatized dyads. Taken together, these findings accurately account for the different excited-state behaviors of the dyads as a function of the level of structural restriction of their intercomponent conformation (and related amplitude for torsional fluctuations), thus providing theoretical evidence of conformationally gated photoinduced electron- and energy-transfer processes.

Fluorometry↗

New multichannel kinetic spectrophotometer-fluorimeter with pulsed measuring beam for photosynthesis research.

A multichannel kinetic spectrophotometer-fluorimeter with pulsed measuring beam and differential optics has been constructed for measurements of light-induced absorbance and fluorescence yield changes in isolated chlorophyll-proteins, thylakoids and intact cells including algae and photosynthetic bacteria. The measuring beam, provided by a short (2 micros) pulse from a xenon flash lamp, is divided into a sample and reference channel by a broad band beam splitter. The spectrum in each channel is analyzed separately by a photodiode array. The use of flash measuring beam and differential detection yields high signal-to-noise ratio (noise level of 2 x 10(-4) in absorbance units per single flash) with negligible actinic effect. The instrument covers a spectral range between 300 and 1050 nm with a spectral resolution of 2.1, 6.4 or 12.8 nm dependent on the type of grating used. The optical design of the instrument enables measuring of the difference spectra during an actinic irradiation of samples with continuous light and/or saturation flashes. The time resolution of the spectrophotometer is limited by the length of Xe flash lamp pulses to 2 micros.

Fluorometry↗

Twelve different enzyme assays on dried-blood filter paper samples for detection of patients with selected inherited lysosomal storage diseases.

BACKGROUND: Diagnoses of inherited lysosomal storage diseases are based on specific enzymatic assays performed on plasma, leukocytes, fibroblasts, and lately, dried-blood filter paper samples. We evaluated feasibility of detecting of patients with several inherited lysosomal storage diseases using dried-blood filter paper samples for appropriate enzyme assays. METHODS: Fluorometric methods were used to evaluate the activities of arylsulfatase B, alpha-N-acetylglucosaminidase, chitotriosidase, alpha and beta-galactosidases, beta-glucosidase, beta-glucuronidase, total hexosaminidases, hexosaminidase A, alpha-iduronidase, and iduronate-2-sulfatase. A radiometric method was used for sphyngomyelinase determination. Single 3.0-mm diameter disks containing dried-blood samples were incubated at 37 degrees C with appropriate dilution buffers and artificial substrates, and the fluorescence or radioactivity was measured. RESULTS: Our results showed a statistically significant difference of the enzyme activity between affected individuals and controls, in all the assays performed. In contrast, we have not obtained a complete differentiation between heterozygotes and controls with these assays. CONCLUSIONS: Enzyme assay on dried-blood filter paper is a suitable method to screen for several lysosomal storage diseases. Despite the low individual incidence of these pathologies, the incorporation of individual enzyme assays in neonatal screening programs could be justified to screen for diseases with relatively high local frequency and therapeutic measures available.

Fluorometry↗