PubMed Health⌕ Search

PubMed · 14709997

Results with titanium ossicular reconstruction prostheses.

Abstract

OBJECTIVES/HYPOTHESIS: Despite the enthusiasm of recent short-term reviews, no center in the United States has published results meeting American Academy of Otolaryngology-Head and Neck Surgery guidelines with titanium-based prostheses. The purpose of the study was threefold. The first purpose was to review results with a titanium prosthesis system in cases meeting American Academy of Otolaryngology-Head and Neck Surgery reporting guidelines. The second was to compare these results with previously published results using non-titanium-based prostheses. The third was to examine the authors' results for any evidence of a "learning curve." STUDY DESIGN: Retrospective chart review was performed for the period from February 2000 to August 2001 and for the period from July 2002 to February 2003. METHODS: Of 313 cases, 130 consecutive cases were identified in the first period and 65 in the second time period. One hundred two patients had adequate follow-up for published guidelines. All cases were performed by the senior author (c.g.j.). Comparison data were obtained from a previous publication involving the senior author. RESULTS: Successful rehabilitation (<or=20 dB pure-tone average air-bone gap) of conductive hearing loss was obtained in 70% of partial ossicular chain reconstructions and 44% of total ossicular chain reconstructions when titanium prostheses were used. Comparison data revealed successful rehabilitation in 48% and 21% of non-titanium-based partial and total reconstructions, respectively. Postoperative pure-tone average air-bone gaps were not significantly different when compared with results in the period from July 2002 to February 2003. CONCLUSION: Newer titanium-based ossicular reconstruction devices represent an improvement over previously used non-titanium-based prostheses. The authors think that this improvement is realized rapidly because no learning curve existed in their data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Edward K Gardner, C Gary Jackson, David M Kaylie. 2004. Results with titanium ossicular reconstruction prostheses.. https://doi.org/10.1097/00005537-200401000-00011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Canal atresia: "surgery or implantable hearing devices? The expert's question is revisited".

OBJECTIVES: (1) Evaluate hearing results in patients managed with external auditory canal reconstruction; (2) compare results to the expectations from treatment with surgical; placement of an osteo-integrated bone-conduction device (BAHA system); (3) assess complications of both interventions; (4) evaluate the medical cost-effectiveness of each avenue of management at 2005 rates for billings based upon relative value units (RVUs). METHODS: (1) Retrospective chart review for 36 ears in 29 pediatric patients who underwent surgical canal reconstruction at a tertiary-care pediatric hospital in a major urban center with assessment of management techniques and surgical and audiologic outcomes. (2) Retrospective chart review of six pediatric patients who underwent BAHA placement in a major urban center with assessment of management techniques and surgical and audiologic outcomes. (3) Cost reassessment at 2005 billings rates based upon RVUs for canal reconstruction versus BAHA system and comparative analysis. RESULTS: (1) The average post-operative hearing loss in the right ear was 34.3 dB left ear was 31.6 dB. The average gain per ear was 17.3 dB. (2) Twenty-seven (93%) of EAC reconstruction patients required some form of amplification post-operatively. (3) Data available for three of the BAHA patients reflected the predicted average gain in dB (predicted 34.3 dB, observed 31.8 dB). (4) Early complications of canal reconstruction included removal of the packing by the patient, post-operative bleeding and post-operative hematoma. (5) Late complications included recurrent canal stenosis, recurrent otitis externa, canal prolapse and canal cholesteatoma. (6) Uncomplicated external auditory canal reconstruction cost $51,505.98 or $2909.94/dB of hearing gain based upon billings fro RVUs. (7) Uncomplicated two-staged BAHA system placement cost $42,448.85 or $1237.57/dB of hearing gain based upon billings for RVUs. (8) Uncomplicated single-staged BAHA system placement cost $28,341.00 or $826.27/dB of hearing gain based upon billings for RVUs. CONCLUSIONS: Study results indicate that even with significant investments in EAC reconstruction, most patients still required some form of amplification. There are also significant risks of early and late complications from the reconstructive procedure. Studies indicate and our results support that the osteo-integrated bone-conduction device (BAHA system) can achieve truly acceptable hearing (<or=15 dB) in school-aged children with normal bone curves, and it can match the bone-curves for children with sensorineural hearing loss. The two-staged BAHA system placement may be provided at almost one-third the cost to the medical system, on a decibel-for-decibel basis. The single-stage BAHA system placement yields even greater cost savings at just over one-quarter of the cost of surgical EAC reconstruction on a decibel-for-decibel basis. Additionally, there are fewer complications and fewer follow-up visits for the care of the implant system. This is an added value to the parents and patient for the savings in opportunity costs related to the lost time at work and school for office visits and peri-operative care. Overall, it appears that osteo-integrated bone-conduction devices may provide a higher quality of outcome for patients while resulting in significant economic savings.

Bone Conduction↗

A finite element model of the human head for auditory bone conduction simulation.

In order to investigate the mechanisms of bone conduction, a finite element model of the human head was developed. The most important steps of the modelling process are described. The model was excited by means of percutaneously applied forces in order to get a deeper insight into the way the parts of the peripheral hearing organ and the surrounding tissue vibrate. The analysis is done based on the division of the bone conduction mechanisms into components. The frequency-dependent patterns of vibration of the components are analyzed. Furthermore, the model allows for the calculation of the contribution of each component to the overall bone-conducted sound. The components interact in a complicated way, which strongly depends on the nature of the excitation and the spatial region to which it is applied.

Bone Conduction↗