[Low-flow anesthesia systems].

Abstract

At present, when economy and environment receive high priority, the ideal anaesthesia system with inhalation anaesthetics is a closed circle system in which only the gases which the patient consumes or produces are replaced or eliminated. Low-flow (LF) anaesthesia in which the fresh gas flow which is employed in a closed system, provides a stable system compares with closed anaesthesia systems. Compared with open systems and circler systems with considerable fresh gas flow, the LF system provides advantages as regards economy, environment and exposure of staff to inhalation anaesthetics. The special conditions involved in LF anaesthesia are described in detail with the hope that the method will obtain more widespread distribution than is the case in Denmark today. If greater safety under anaesthesia is desired, eg by monitoring the concentrations of CO2, O2 and inhalation anaesthetics which the patients inspire and expire, this monitoring equipment can be financed by introduction of LF anaesthesia.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Reinstrup, P Slots, B C Jørgensen. 1992-12-07. [Low-flow anesthesia systems].. https://pubmed.ncbi.nlm.nih.gov/1471275/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Closed anesthetic systems].

Anaesthesia with closed anaesthetic systems demands knowledge of the physiology of the patients and of how the various anaesthetic gases behave in the organism as only the gases which the patients produces and absorbs are eliminated and replaced. The system is educational as it provides knowledge of the genuine absorption of oxygen and anaesthetic gases. The method is favourable to the environment as only the gases which are used are supplied and it is thus economical in use although investment in monitoring equipment is necessary. In practice, induction and waking of the patient are complicated with this system and it requires an anaesthetist who constantly adjusts the gases in the circuit.

Anesthesia, Closed-Circuit

Noninvasive cardiac output determined with a new method based on gas exchange measurements and carbon dioxide rebreathing: a study in animals/pigs.

A system has been designed to determine cardiac output noninvasively. The system's main component is a closed breathing circuit and it measures oxygen uptake (VO2), carbon dioxide elimination (VCO2), and end-tidal CO2 partial pressure (PET). As an integral part of the system, periods of CO2 rebreathing can be automatically implemented. The CO2 partial pressure of oxygenated mixed venous blood (Pv) is obtained from the measured exponential rise of the PET value during such a CO2 rebreathing maneuver. A new method is described for estimating the pulmonary blood flow, alveolar ventilation, cardiac output (CO), and mixed venous oxygen saturation (SVO2) from PV, PET, VO2, VCO2, tidal volume, and arterial oxygen saturation. The method was evaluated in 6 anesthetized and mechanically ventilated pigs. A wide range of cardiac output, shunt fractions, and dead space to tidal volume ratios were induced by combinations of bronchoalveolar lavage, hypervolemia, hypovolemia, and variable levels of positive end-expiratory pressure (PEEP). The bias between the CO obtained with the noninvasive technique (CO L/min) and the thermodilution CO (Qt L/min) was 0.13 L/min (SD = 0.78 L/min) and the correlation was N = 64; R = 0.92; CO = 0.95*Qt + 0.38. The bias obtained for double determinations with the noninvasive CO technique was 0.3 L/min (SD = 0.5 L/min). The bias between the noninvasive estimates of Svo2 and the directly measured values was 1.1% (SD = 9.3%). For double determination with the noninvasive technique the bias was -0.9% (SD = 4.7%). It is concluded that in mechanically ventilated pigs the proposed method produces good estimates of CO and SVO2 also in the presence of significant ventilation/perfusion mismatch.

Anesthesia, Closed-Circuit