PubMed Health⌕ Search

PubMed · 14713385

The perennial problem with potassium.

Abstract

BACKGROUND: The problem of spurious hyperkalaemia in blood samples delivered to hospitals from local general practitioners' (GP) surgeries remains a source of diagnostic confusion and potential danger to patients. We have carried out retrospective and prospective audits of serum potassium measurements to assess the influences of blood sample delivery time and temperature during transit from GP surgeries to a centralized laboratory on the risk of spurious serum potassium measurements. METHOD: The retrospective audit included serum potassium measurements made by the pathology laboratory at Addenbrooke's Hospital on 51 843 patients attending either the hospital itself or one of 62 local GP surgeries during the months August 2001 to February 2002 (i.e. summer through to winter). The probability of spurious potassium measurements on GP patients relative to blood sample delivery time and temperature was modelled by least-squares multiple linear regression. The prospective audit included serum potassium measurements made on 40 patients presenting early in the day at the Sutton GP surgery near Ely, Cambridgeshire, during the months February to May 2002. RESULTS: Low blood sample delivery temperature had a greater impact on the probability of spurious potassium measurements than long delivery time. Low delivery temperature also had a greater impact on the probability of spurious hyperkalaemia than it had on the probability of spurious normokalaemia. At temperatures below 20.3 degrees C, the probabilities of both spurious hyper- and normokalaemia for samples delivered from the most distant and closest GP surgeries to Addenbrooke's increased significantly. CONCLUSIONS: Maintaining blood sample delivery temperatures a few degrees above 20 degrees C will minimize the risk of spurious serum potassium measurements on samples from GP patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Andrew K Trull, Christopher Jackson, Sarah Walsh, Andi Thornton, Leslie S Culank, John McHugh. 2004. The perennial problem with potassium.. https://doi.org/10.1258/000456304322664690

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Novel diagnostic approach to citrin deficiency: analysis of citrin protein in lymphocytes.

Citrin deficiency induces two clinical features; namely neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD) and adult-onset type II citrullinemia. Hypercitrullinemia is the most characteristic feature, whereas there are non-citrullinemic individuals. Diagnosis of citrin deficiency is performed by genetic analysis, although the 12 known mutations in the alleles are not detected in about 15% of cases. Thus, we aimed to examine citrin protein in lymphocytes isolated from peripheral blood as an alternative diagnostic method. We examined 38 children having an episode of cholestatic liver dysfunction, 8 heterozygotes, and 11 healthy individuals. All subjects were evaluated for citrin protein by Western blotting and for the 12 known mutations by gene analysis. Citrin protein was detected in 15 of 38 children with cholestatic liver dysfunction. Fourteen of them were negative for 12 known mutations in both alleles, whereas one patient was found to have a known mutation in one allele. Citrin protein was absent in 23 of the 38 patients. Among these 23, gene analysis diagnosed citrin deficiency in 19, whereas 2 patients were later revealed to be NICCD with novel mutations. In the remaining 2 patients, who exhibit the clinical features of NICCD, a known mutation was detected in one allele but no mutation was identified in another allele. Citrin protein was also detected in the 8 heterozygotes and 11 healthy individuals. We disclosed that citrin was deficient in lymphocytes among patients with citrin deficiency. Analysis of citrin is useful to diagnose citrin deficiency even in patients without known mutations or hypercitrullinemia.

Blood Preservation↗

Substantial improvements in performance indicators achieved in a peripheral blood mononuclear cell cryopreservation quality assurance program using single donor samples.

Storage of high-quality cryopreserved peripheral blood mononuclear cells (PBMC) is often a requirement for multicenter clinical trials and requires a reproducibly high standard of practice. A quality assurance program (QAP) was established to assess an Australia-wide network of laboratories in the provision of high-quality PBMC (determined by yield, viability, and function), using blood taken from single donors (human immunodeficiency virus [HIV] positive and HIV negative) and shipped to each site for preparation and cryopreservation of PBMC. The aim of the QAP was to provide laboratory accreditation for participation in clinical trials and cohort studies which require preparation and cryopreservation of PBMC and to assist all laboratories to prepare PBMC with a viability of >80% and yield of >50% following thawing. Many laboratories failed to reach this standard on the initial QAP round. Interventions to improve performance included telephone interviews with the staff at each laboratory, two annual wet workshops, and direct access to a senior scientist to discuss performance following each QAP round. Performance improved substantially in the majority of sites that initially failed the QAP (P = 0.002 and P = 0.001 for viability and yield, respectively). In a minority of laboratories, there was no improvement (n = 2), while a high standard was retained at the laboratories that commenced with adequate performance (n = 3). These findings demonstrate that simple interventions and monitoring of PBMC preparation and cryopreservation from multiple laboratories can significantly improve performance and contribute to maintenance of a network of laboratories accredited for quality PBMC fractionation and cryopreservation.

Blood Preservation↗