PubMed Health⌕ Search

PubMed · 14715165

Computerized methods for X-ray-based small bone densitometry.

Abstract

Animal models have been widely used to correlate in vivo changes in bone mineral density (BMD) with changes in disease state of bone. In small animal models, e.g. the hindlimb suspension model of bone loss, a non-invasive assessment of BMD is required. X-ray radiography has been surpassed in some cases by quantitative computed tomography (QCT) and dual X-ray absorptiometry (DEXA) quantitation. However, there are drawbacks in using the computerized methods, especially for small animals. In this paper, we present image-processing algorithms to quantitatively determine bone area and mineral density in digitized radiographs. Image calibration is based on a calibration step wedge, and the algorithm automatically detects the steps and computes the calibration data. In addition, we demonstrate how the algorithm can accurately determine the cortical outline of the bone and provide reliable data and statistics for small animal studies. A downloadable implementation example for the popular NIH Image package is provided.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mark A Haidekker, Hazel Y Stevens, John A Frangos. 2004. Computerized methods for X-ray-based small bone densitometry.. https://doi.org/10.1016/s0169-2607(02)00164-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Greater than predicted decrease in resting energy expenditure with age: cross-sectional and longitudinal evidence.

OBJECTIVE: To determine whether the age-related decrease in resting energy expenditure (REE) is explained by variations in body composition. DESIGN: In Study 1, adult subjects (20-70 years) from the Quebec Family Study were classified into five different age groups. Body composition was measured by hydrodensitometry to determine fat mass and fat-free mass as predictors of REE. In the youngest group of individuals these predictors were used to plot a reference regression that was then used to predict REE in the other age groups. In Study 2, this issue was investigated in a longitudinal design (6-year follow-up). Subjects were subdivided into three groups and a reference regression was plotted at the beginning of the follow-up and was then used to predict REE 6 years later in the three age groups. SUBJECTS: In Study 1, 627 adults (288 men and 339 women), aged between 20 and 70 years. In Study 2, 191 adults (93 men and 98 women). RESULTS: In Study 1, measured REE was 329, 302, 528 and 636 kJ/day (P < 0.0001) below predicted REE at 34, 44, 54 and 64 years, respectively. In Study 2 the most marked deviation from predicted REE in response to the 6-year follow-up in men was observed in young adults (-548 kJ/day, P < 0.001) while in women, the largest deviation occurred later in life (-720 kj/day, P < 0.001). CONCLUSION: Aging is accompanied by a decrease in REE that is significantly greater than what is predicted by variations in body composition. This decrease may reach a mean level of about 500-800 kj/day.

Absorptiometry, Photon↗

Parathyroid hormone is associated with decreased fat mass in young healthy women.

OBJECTIVE: To investigate the relationship of parathyroid hormone (PTH) with dietary calcium and changes in body composition. DESIGN: Cross-sectional and 1-year longitudinal trial. SUBJECTS: Normal-weight young women (age: 18-31), 155 subjects analyzed at baseline, and data for 41 subjects analyzed prospectively between baseline and 12 months. MEASUREMENTS: Levels of fasting serum calcium and PTH, intakes of calcium (3-day diet records), and total body weight and body composition (dual energy X-ray absorptiometry). RESULTS: Baseline dietary calcium, regardless of whether unadjusted or adjusted for energy intake, did not predict baseline levels of fasting serum PTH. Change in dietary calcium also did not predict change in serum PTH. However, log PTH was significantly correlated with body fat mass (R = 0.27), but not lean mass at baseline (n = 155), independent of serum calcium (corrected R = 0.25). Further, 12-month changes (n = 41) in log PTH positively predicted the 12-month change in body weight (R = 0.32) and body fat (R = 0.32), but not lean mass even when controlled for age or change in serum calcium. CONCLUSION: Fasting serum PTH was associated with increased fat mass, in both cross-sectional and prospective analysis. Thus, serum PTH may play a role in the regulation of body fat mass in young women.

Absorptiometry, Photon↗

A simple non invasive computerized method for the assessment of bone repair within osteoconductive porous bioceramic grafts.

Single energy X-ray imaging, due to its low cost and flexibility, is one of the most used and common technique to assess bone state and bone remodeling over time. Standardized X-ray images are needed to compare sets of radiographs for semi-quantitative analyses of tissue remodeling. However, useful mathematical modeling for the analysis of high level radiographic images are not easily available. In order to propose a useful evaluation tool to a wide clinical scenario, we present an innovative calibration algorithm for a semi-quantitative analysis of non-standardized digitized X-ray images. For calibration on a unique standardization scale, three time invariant regions (ROI) of radiographs were selected and analyzed. The accuracy of the normalization method for X-ray films was successfully validated by using an aluminum step wedge for routine X-ray exposures as tool to standardize serial radiographs (Pearson correlation test: R(2) = 0.96). This method was applied to investigate the progression of the new bone deposition within ceramic scaffolds used as osteoconductive substitute in large bone defects taking advantage of a large animal model. This innovative image-processing algorithm allowed the identification and semi-quantification of the bone matrix deposited within the implant. The osteo-integration at the bone-implant interface was also investigated. A progressively increasing bone tissue deposition within the porous bioceramic implant and a progressive osteo-integration was observed during the 12 months of the trial.

Absorptiometry, Photon↗