Flunisolide HFA.

Abstract

Flunisolide is a synthetic corticosteroid approved for the treatment of persistent asthma and delivered by means of a metered-dose inhaler (MDI). A new formulation of flunisolide, using hydrofluoroalkane (HFA) as a propellant, has been developed to comply with the mandated worldwide phase-out of ozone-depleting chlorofluorocarbon (CFC) propellants. Aerosol particle size in the new flunisolide HFA solution is smaller than the flunisolide CFC suspension (1.2 vs 3.8 microm mass median aerodynamic diameter). Aerosol particle size is a key element in determining lung deposition and the regional distribution of inhaled medication within the lung. In addition, the flunisolide HFA MDI has been redesigned to include a built-in spacer. These features have improved distal lung deposition. Flunisolide HFA, at one-third the dosage (170 and 340 microg twice daily), had similar efficacy to flunisolide CFC (500 and 1000 microg twice daily) and significantly greater efficacy than placebo in a randomized, double-blind, placebo-controlled, 12-week study in patients with mild to moderate asthma. Flunisolide HFA was well tolerated in all trials. A long-term study found no suppression of adrenal function and minimal systemic effects were observed both in adults and children.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John Waugh, Karen L Goa. 2002. Flunisolide HFA.. https://doi.org/10.1007/bf03256630

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Medical aerosol propellant interference with infrared anaesthetic gas monitors.

BACKGROUND: 1,1,1,2 Tetrafluoroethane is a hydrofluoroalkane (HFA) that is replacing chlorofluorocarbons (CFC) as a medical aerosol propellant in an attempt to reduce damage to the ozone layer. This study compared the effects of HFA- and CFC-based inhalers on four anaesthetic gas monitoring systems. METHODS: The HFA- and CFC-based inhalers were activated in close proximity to the sample line of two Datex Ohmeda, an Agilent and a Siemens infrared anaesthetic agent monitoring systems. The effects were recorded on each system for five common anaesthetic agents. RESULTS: The HFA inhaler caused either maximal false positive readings (with the exception of desflurane) or transient measurement failure on all systems. The Datex Ohmeda AS/3 system misidentified the HFA inhaler as carbon dioxide at low concentration (2 +/- 0 mm Hg). The CFC-based inhaler caused a minor false-positive reading (0.4 +/- 0%) for halothane only on the Datex Ohmeda AS/3 system only and was misidentified as carbon dioxide at 33.3 (sd 2.1) mm x Hg and 22.4 (8.9) mm x Hg by the Agilent and Siemens systems. CONCLUSIONS: The HFA inhaler adversely affected all equipment tested. The infrared spectra of HFA and the common anaesthetic gases have considerable overlap at the 8-12 microm range that is not shared by the CFCs. The differences in spectral overlap explain the different effects of the HFA and CFC propellants. Anaesthetic gas concentration data may be erroneous using the HFA-based inhalers.

Aerosol Propellants↗

The influence of formulation and spacer device on the in vitro performance of solution chlorofluorocarbon-free propellant-driven metered dose inhalers.

The purpose of this study was to evaluate the hypothesis that spacer devices have limited effect on the in vitro fine particle dose emitted from solution metered dose inhalers containing different proportions of HFA134a [1,1,1,2,-tetrafluoroethane] propellant. Two solution formulations (80% and 97.5% wt/wt HFA134a) were tested across the actuator alone, actuator plus Aerochamber, and Ace holding chamber. Particle size distributions were determined using laser diffraction (LD) and cascade impaction (CI). Multimodal particle size distributions were identified using LD. CI analyses were characterized by a major mode located at approximately 0.5 microm. The fine particle dose emitted from the inhaler spacer combinations containing 97.5% HFA134a was independent of the device setup used. Fine particle doses were influenced by spacer setup in 80% HFA134a formulations, indicating different plume dynamics of low vapor pressure formulations. Sampling inlet deposition was approximately 0 when spacer devices were used with either formulation. When spacers were not used, sampling inlet deposition was increased significantly. However, inlet deposition with the 97.5% HFA134a formulation was significantly less than that of the 80% HFA134a formulation (approximately 25% of emitted dose compared with 69%, respectively). Thus, high propellant concentration formulations appear to have more robust in vitro performance. This is particularly important given the preponderance of poor patient compliance that is associated with spacer use. High propellant concentrations had the advantage of fine particle doses that were independent of the device setup and significantly lowered sampling inlet deposition when no spacer was used.

Aerosol Propellants↗