Microfluidic approaches to malaria detection.

Abstract

Microfluidic systems are under development to address a variety of medical problems. Key advantages of micrototal analysis systems based on microfluidic technology are the promise of small size and the integration of sample handling and measurement functions within a single, automated device having low mass-production costs. Here, we review the spectrum of methods currently used to detect malaria, consider their advantages and disadvantages, and discuss their adaptability towards integration into small, automated micro total analysis systems. Molecular amplification methods emerge as leading candidates for chip-based systems because they offer extremely high sensitivity, the ability to recognize malaria species and strain, and they will be adaptable to the detection of new genotypic signatures that will emerge from current genomic-based research of the disease. Current approaches to the development of chip-based molecular amplification are considered with special emphasis on flow-through PCR, and we present for the first time the method of malaria specimen preparation by dielectrophoretic field-flow-fractionation. Although many challenges must be addressed to realize a micrototal analysis system for malaria diagnosis, it is concluded that the potential benefits of the approach are well worth pursuing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peter Gascoyne, Jutamaad Satayavivad, Mathuros Ruchirawat. 2004. Microfluidic approaches to malaria detection.. https://doi.org/10.1016/j.actatropica.2003.11.009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Biodegradability of imidazolium and pyridinium ionic liquids by an activated sludge microbial community.

Ionic liquids (ILs) are novel organic salts that have enormous potential for industrial use as green replacements for harmful volatile organic solvents. Varying the cationic components can alter the chemical and physical properties of ILs, including solubility, to suit a variety of industrial processes. However, to complement designer engineering, it is crucial to proactively characterize the biological impacts of new chemicals, in order to fully define them as environmentally friendly. Before introduction of ILs into the environment, we performed an analysis of the biodegradability of six ILs by activated sludge microorganisms collected from the South Bend, Indiana wastewater treatment plant. We examined biodegradability of 1-butyl, 1-hexyl and 1-octyl derivatives of 3-methyl-imidazolium and 3-methyl-pyridinium bromide compounds using the standard Organisation for Economic Cooperation and Development dissolved organic carbon Die-Away Test, changes in total dissolved nitrogen concentrations, and 1H-nuclear magnetic resonance analysis of initial and final chemical structures. Further, we examined microbial community profiles throughout the incubation period using denaturing gradient gel electrophoresis (DNA-PCR-DGGE). Our results suggest that hexyl and octyl substituted pyridinium-based ILs can be fully mineralized, but that imidazolium-based ILs are only partially mineralized. Butyl substituted ILs with either cation, were not biodegradable. Biodegradation rates also increase with longer alkyl chain length, which may be related to enhanced selection of a microbial community. Finally, DGGE analysis suggests that certain microorganisms are enriched by ILs used as a carbon source. Based on these results, we suggest that further IL design and synthesis include pyridinium cations and longer alkyl substitutions for rapid biodegradability.

Electrophoresis↗

Electrophoretic separation of human skeletal muscle myosin heavy chain isoforms: the importance of reducing agents.

An electrophoretic protocol previously used for the separation of rat myosin heavy chain (MHC) isoforms was slightly modified to improve the separation of human MHC isoforms in both large and minigel systems. The addition of reducing agents (beta-mercaptoethanol or dithiothreitol) to the top running buffer (TRB) radically improved separated MHC isoform resolution and the intensity of electrophoretic runs lasting longer than 5 h. In minigel systems, the MHC isoforms could be separated in as little as 5 h. The improved resolution of bands with the inclusion of reducing agents to the TRB facilitated the identification of clear boundaries for densitometric quantification of relative MHC isoform content, particularly for MHC IIa and MHC IIx. No significant effect of these reducing agents added to the TRB was observed for runs lasting only 100 min. Thus the inclusion of reducing agents in the TRB is essential for long electrophoretic runs, usually when separating large molecular mass proteins.

Electrophoresis↗