Frequency measuring system using mirror gap stabilized Fabry-Perot interferometer.

Abstract

The mirror gap of a Fabry-Perot interferometer was stabilized with two laser diodes; one locked to the line frequency 385,243,555.14445 MHz of the F=3<--1 in 5D(3/2)<--5S(1/2) (87Rb) and the other to the 385,284,566.3663 MHz of the F=4<--2 in 5D(5/2)<--5S(1/2) (87Rb) [Opt. Commun. 102 (1993) 432]. The length of the mirror gap was adjusted to generate the zero-cross points simultaneously at both of the two line positions. The fringe signals obtained from an interferometer thus stabilized can be used as frequency markers having accuracies of the order of 10(10) depending on the finesse of the interferometer used. Based on measurement using Cs D1 hyperfine lines reported by Udem et al. [Phys. Rev. Lett. 82 (1999) 3568], the uncertainty of markers in the region 50 THz apart from the reference lines is +/- 5 MHz.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nobuo Nishimiya, Yoko Yamaguchi, Yoshinobu Ohrui, Masao Suzuki. 2004. Frequency measuring system using mirror gap stabilized Fabry-Perot interferometer.. https://doi.org/10.1016/s1386-1425(03)00222-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transpalpebral tonometry with a digital tonometer in healthy eyes and after penetrating keratoplasty].

PURPOSE: The Goldmann applanation technique established itself as gold standard for clinical intraocular pressure (IOP) measurement. But the device measures by corneal touch and presupposes corneal conditions within a normal range. So precise determination of IOP is crucial in corneal disorders and after corneal surgery. This pilot study presents tonometry data of normal and postkeratoplasty eyes measured transpalpebrally with a digital tonometer in comparison to Goldmann tonometry. METHOD: The TGDc-01 tonometer is based on a ballistic principle of measurement. IOP was measured in 50 healthy eyes (group 1) and 40 eyes after penetrating keratoplasty (group 2) first by the TGDc-01 and after 3 minutes by Goldmann tonometry (Haag-Streit). Subjective refraction, keratometry and ultrasonic pachymetry were performed in all eyes. The IOP measurements in the postkeratoplasty eyes were done when corneal epithelium was fully closed and only a medium suture edema could be observed. RESULTS: The Pearson's product-moment correlation was r=0,46 for group 1 and 0,65 for group 2. Using the concordance correlation coefficient the value showed a reproducibility index of r(c)=0,44 in group 1 and r(c)=0,60 in group 2. Following the Bland-Altman-analysis 58% of the cases in group 1 had a difference between the two instruments of maximum 3 mmHg. In group 2, 53,5% of the eyes showed an absolute difference between Goldmann and TDGc-01 of 3 mmHg or less. CONCLUSION: A transpalpebral measurement technique-avoiding corneal contact-seems to be an alternative choice in patients with corneal pathologies and after corneal surgery. The TGDc-01 tonometer provided mostly similar results compared to the Goldmann device, but with fluctuations. Keeping the deviations between the two methods in mind we recommend, however, the use of the transpalpebral approach only in combination with other techniques (palpation, indentation) to obtain enough reliability of IOP information in problem eyes.

Data Interpretation, Statistical↗

Detecting interregionally diversifying natural selection on modern human cranial form by using matched molecular and morphometric data.

This comparison of morphological and neutral genetic variation in 10 human populations was designed to test a neutral hypothesis of cranial evolution in living and recent humans and to explain deviations from neutrality where detected. Overall, among-population differences in extant Homo sapiens cranial morphology are proportional to among-population differences in neutral molecular characteristics. For most of the populations studied, cranial morphology varies among regions in a manner consistent with neutral expectations. Removal of the effects of shared population history and structure by using the partial Mantel's test, however, does not remove the correlation between some aspects of cranial morphology and a measure of coldness of climate. The excess differentiation is most apparent in those population comparisons that involve a Siberian population living in an extremely cold environment. This finding suggests the action of natural selection, associated with regional variation in temperature, leading to among-population differentiation in excess of neutral expectations for some cranial dimensions. Those dimensions reflect the breadth of the skull, cranial vault size and shape, and aspects of nasal morphology. Although morphology for most of the world appears to vary among populations in accordance with neutral expectations in the context of population structure and history, morphology of the Siberian population appears to have undergone adaptation by natural selection.

Data Interpretation, Statistical↗