[A study of 11 ventilators for anesthesia: laboratory testing].

Abstract

Eleven anaesthesia ventilators were instrumentally tested under various conditions. They included: Excel and Modulus II Plus (Ohmeda); 710 and Servo anaesthesia circle 985 (Siemens); Jollytronic (Soxil) and Elsa (Engström); SA2 and Cicero (Dräger); ABT 4,300 (Kontron); Monnal A and the prototype Alys (Taema). The test circuit comprised a two compartment model lung, a pneumotachograph, a pressure gauge in the "airway". The volume was calculated as the integral of flow rate. Each machine was calibrated by the firms' technicians. Before each test, the pneumotachograph was calibrated using a 11 air syringe and the pressure gauge with a 5 cm water column. Each machine ventilated the model lung for 30 min before starting the tests. There were five tests: 1) reliability of the machine's spirometer, 2) reliability of the ventilation rate, 3) reliability of pressure measurements, 4) effect of increasing fresh gas flow on spirometry, 5) effect of increasing downstream resistances. In usual simulated ventilatory conditions, all the machines accurately delivered the setted ventilation and spirometric measurements were with minimal error only. Several ventilators (SA2, Excel, 710, Elsa, ABT 4,300) did not succeed in maintaining their performances when compliance was strongly decreased or resistance of the test lung notably increased. Resistance in the circuit during simulated spontaneous ventilation was < 3.6 cmH2O.l-1.s-1. Increasing fresh gas flow raised the minute volume delivered in six ventilators. It is concluded that, during extreme ventilatory conditions, the inspired volume must be adjusted so as to maintain the inspired tidal volume. However, ventilators which increase inspiratory time in response to an increased mechanical load cannot be adjusted by this way.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Liu, L Beydon, B Bach, F Bonnet, F Clergue, S Fougere, Y Louville, Y Nivoche. 1992. [A study of 11 ventilators for anesthesia: laboratory testing].. https://doi.org/10.1016/s0750-7658(05)80755-5. https://pubmed.health/record/pubmed%3A1476281/a-study-of-11-ventilators-for-anesthesia-laboratory-testing

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Minimal access thoracic surgery in the pediatric population.

Thoracoscopy was initially described for use in children to obtain pulmonary biopsy samples in the immunocompromised patient. With refinements in technique, development of better instrumentation, and advances in pediatric anesthesia, there are now many diagnostic and therapeutic indications for the use of thoracoscopy in children. One of the most common indications includes pleural debridement for empyema. Many centers consider this the optimal approach for biopsy of mediastinal lesions and excision of bronchogenic or duplication cysts. The technique is useful for pleural disorders, such as spontaneous pneumothorax and chylothorax. Thoracoscopy has been used to achieve exposure for spinal diskectomy in children with thoracic scoliosis, and newer techniques are being developed in performing anatomic lobectomies, repair of esophageal atesias, and closure of diaphragmatic hernias. The role of the robot in pediatric thoracoscopy is still in the early stages of definition.

Anesthesia, Closed-Circuit↗

Closed system anaesthesia--historical aspects and recent developments.

Closed circuit anaesthesia was described decades ago but did not achieve wide popularity among anaesthesiologists mainly because reliable control of inspiratory gas concentrations was not possible. Recent innovations including fast gas analysers, electronically controlled dosage systems and algorithms for feedback control have made possible the development of sophisticated closed circuit ventilators designed for routine clinical practice. The main advantages comprise economic use of medical gases and volatile anaesthetics, reduction of anaesthetic gas loss into the atmosphere, improved airway acclimatization as well as estimations of oxygen consumption. This article reviews historical aspects, recent developments as well as advantages and limitations of closed system anaesthesia.

Anesthesia, Closed-Circuit↗