PubMed HealthSearch

PubMed · 1486785

Cardiac fluid dynamics.

Abstract

The heart is modeled as a system of elastic and/or contractile fibers immersed in a viscous incompressible fluid. Simulated heart walls and valves are constructed by arranging the fibers according to an idealized version of the actual distribution of muscle fibers in the heart walls and collagen fibers in the valve leaflets. Then the combined motion of the fluid-fiber system is predicted through the numerical solution of its coupled equations of motion. Fluid equations are solved by a finite difference method on a fixed, regular computational lattice. Fiber points move freely through this lattice without being constrained to lie at the lattice intersections. Communication between fibers and fluid involves interpolation of the fluid velocity to the fiber points and the spreading of the fiber forces to the computational lattice of the fluid. Both of these operations make use of a smoothed approximation to the Dirac delta function. The entire method is suitable for implementation on vector, parallel, or parallel-vector hardware. Applications include the investigation of normal cardiac function, the simulation of disease processes affecting the mechanical function of the heart or its valves, and the computer-assisted design of prosthetic cardiac valves.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C S Peskin, D M McQueen. 1992. Cardiac fluid dynamics.. https://pubmed.ncbi.nlm.nih.gov/1486785/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transcatheter umbrella closure of valvular and paravalvular leaks.

OBJECTIVES: Our aim was to adapt the technique of transcatheter umbrella closure of intracardiac defects for closure of valvular and paravalvular defects. BACKGROUND: The double-umbrella device developed by Rashkind and Cuaso has been safely and effectively delivered across a host of intracardiac defects, but transcatheter closure of valvular and paravalvular leaks has not been reported. METHODS: Between February 1987 and September 1990, eight patients who were believed to be poor operative candidates were taken to the catheterization laboratory for transcatheter double-umbrella closure of a valvular or a paravalvular leak. Four patients had a paravalvular leak around a prosthetic aortic valve. The other four patients had a valvular leak: one patient with a regurgitant native aortic valve after a Stansel procedure and three patients with a regurgitant porcine valve in a left ventricular apex to descending aorta conduit. RESULTS: Placement of a double-umbrella device was attempted in seven of the eight patients and was successful in all seven. Device placement was not attempted in one patient because of the crescentic shape of his defect. Two patients required two devices for each closure; the other five required only one device each. Angiography, performed on six patients after device closure, demonstrated that three patients had a completely occluded defect, two had trivial residual flow and one patient had mild residual flow through the device. All significant complications occurred in one patient who had hemolysis and oliguria that resolved when the initial umbrella was replaced by a larger device. In addition, two devices migrated to the patient's pulmonary arteries but were retrieved in the catheterization laboratory without difficulty. No other early or late complications occurred in 21 to 50 months of follow-up. Of the four patients with a paravalvular leak, the one who did not receive a device died at operation, one patient died at operation for an associated defect (in the operating room the umbrella was found securely in place across the paraaortic defect) and two patients are clinically well at home after 21 and 32 months, respectively. Of the four patients with closure of a valvular leak, one patient remains well at home 50 months later, one patient died at operation for associated defects and two patients had additional successful surgical treatment and remain well 29 months after device placement. CONCLUSIONS: Transcatheter umbrella closure appears to be a reasonable alternative for closure of a valvular or paravalvular leak in patients who are poor operative candidates.

Aortic Valve

[Results of heart valve replacement. Prognosis--occupational and general disability--occupational rehabilitation].

The success of valve surgery has led to a marked improvement in prognosis, quality of life and exercise tolerance in patients with symptomatic valvular heart disease. The degree of subjective and objective improvement depends on multiple preoperative factors like NYHA status, left ventricular function, valve lesion and type of valve replaced as well as peri- and postoperative factors like the occurrence of a perioperative myocardial infarction, the degree of intraoperative myocardial damage, the type of valve replaced and the speed and degree of postoperative regression of left ventricular hypertrophy and dilatation. The postoperative exercise tolerance is a major determinant for postoperative vocational rehabilitation. Therefore the individual functional assessment of patients postoperatively is of major importance.

Aortic Valve