PubMed Health⌕ Search

PubMed · 1489675

First principles of fast spin echo.

Abstract

Fast spin echo (FSE), a variant of the rapid acquisition with refocused echoes pulse sequence, is now being widely considered as an alternative to conventional spin echo for proton density and T2-weighted imaging. Although the medical experience with this sequence is relatively limited, relevant aspects of the technique have been well understood in the context of spectroscopic applications for many years. This article attempts to portray the subject in an appropriate historical context. Such a viewpoint promotes a deeper understanding of the artifacts, determinants of contrast, and future evolution of FSE. Hopefully, this may not only be of benefit in the design of optimal clinical imaging protocols for current state of the art but may also be of use in fashioning the criteria by which new developments in this field may be judged.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Listerud, S Einstein, E Outwater, H Y Kressel. 1992. First principles of fast spin echo.. https://pubmed.ncbi.nlm.nih.gov/1489675/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗