PubMed Health⌕ Search

PubMed · 14926675

Prosthesis.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N R E FENDALL. 1952. Prosthesis.. https://pubmed.ncbi.nlm.nih.gov/14926675/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development of an integrated CAD-FEA process for below-knee prosthetic sockets.

BACKGROUND: Computer-aided design and manufacturing has been successfully used in prosthetic applications since 1980s. It simplifies the socket rectification process and improves reproducibility but does not introduce any new principle into socket design. Integrating finite element analysis to CAD will provide a more objective assessment of socket fit and improve the chance of a successful first fitting. METHODS: Current study aims to establish a finite element model generation technique directly from geometrical information of commercial prosthetic CAD workstation. A program developed in-house automatically performs meshing of the stump geometry and assigns suitable material properties, load and boundary conditions to the model. The model was validated by comparing predicted pressure with experimentally measured values for one amputee subject. FINDINGS: The predicted pressure distribution has an root-mean-square error of 8.8 kPa compared to experimental values at 10%, 25% and 50% of the gait cycle. INTERPRETATION: Current method was able to develop a finite element model to predict interface pressure reasonably well and can be integrated with prosthetic CAD system to provide quantitative feedback to the prosthetist in an automated process.

Artificial Limbs↗

A quasi-dynamic nonlinear finite element model to investigate prosthetic interface stresses during walking for trans-tibial amputees.

BACKGROUND: To predict the interface pressure between residual limb and prosthetic socket for trans-tibial amputees during walking. METHODS: A quasi-dynamic finite element model was built based on the actual geometry of residual limb, internal bones and socket liner. To simulate the friction/slip boundary conditions between the skin and liner, automated surface-to-surface contact was used. Besides variable external loads and material inertia, the coupling between the large rigid displacement of knee joint and small elastic deformation of residual limb and prosthetic components were also considered. RESULTS: Interface pressure distribution was found to have the same profile during walking. The high pressures fall over popliteal depression, middle patella tendon, lateral tibia and medial tibia regions. Interface pressure predicted by static or quasi-dynamic analysis had the similar double-peaked waveform shape in stance phase. INTERPRETATION: The consideration of inertial effects and motion of knee joint cause 210% average variation of the area between the pressure curve and the horizontal line of pressure threshold between two cases, even though there is only a small change in the peak pressure. The findings in this paper show that the coupling dynamic effects of inertial loads and knee flexion must be considered to study interface pressure between residual limb and prosthetic socket during walking.

Artificial Limbs↗