PubMed Health⌕ Search

PubMed · 14971509

Low-dispersion electrokinetic flows for expanded separation channels in microfluidic systems: multiple faceted interfaces.

Abstract

A novel methodology to design on-chip conduction channels is presented for expansion of low-dispersion separation channels. Designs are examined using two-dimensional numerical solutions of the Laplace equation with a Monte Carlo technique to model diffusion. The design technique relies on trigonometric relations that apply for ideal electrokinetic flows. Flows are rotated and stretched along the abrupt interface between adjacent regions having differing specific permeability. Multiple interfaces can be placed in series along a channel. The resulting channels can be expanded to extreme widths while minimizing dispersion of injected analyte bands. These channels can provide a long path length for line-of-sight optical absorption measurements. Expanded sections can be reduced to enable point detection at the exit section of the channel. Designed to be shallow, these channels have extreme aspect ratios in the wide section, greatly increasing the surface-to-volume ratio to increase heat removal and decrease unwanted pressure-driven flow. The use of multiple interfaces is demonstrated by considering several three-interface designs. Faceted flow splitters can be constructed to divide channels into any number of exit channels while minimizing dispersion. The resulting manifolds can be used to construct medians for structural support in wide, shallow channels.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gregory J Fiechtner, Eric B Cummings. 2004-02-20. Low-dispersion electrokinetic flows for expanded separation channels in microfluidic systems: multiple faceted interfaces.. https://doi.org/10.1016/j.chroma.2003.08.050

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Recent progress in the use of ionic polymers as pseudostationary phases for EKC.

This review concerns the introduction, characterization, and application of polymeric pseudostationary phases (PSPs) for EKC since 2004. Achiral and chiral polymers and separations are reviewed, as is the application of polymeric PSPs for the combination of EKC with mass spectrometric detection.

Chromatography, Micellar Electrokinetic Capillary↗

MEKC: an update focusing on practical aspects.

This paper reviews recent methodological and instrumental advances in MEKC. Improvements in sensitivity arising from the use of on-line sample concentration (sweeping, stacking, and combination of both protocols) and derivatization (in-capillary reactions and coupling with flow-injection systems) and improvements in resolution obtained by changing the composition of the BGE (e.g., with organic modifiers, ionic liquids, nonionic and zwitterionic surfactants, mixed micelles, and vesicles) or using coated capillaries are discussed in detail. In addition, MS and LIF spectroscopy are examined in relation to their advantages and restrictions as applied to MEKC analysis. Some thoughts on potential future directions are also expressed.

Chromatography, Micellar Electrokinetic Capillary↗

Comparison of migration models for acidic solutes in micellar electrokinetic chromatography.

The validity of two models that explain the migration of ionisable solutes in micellar electrokinetic chromatography (MEKC), mobility model and retention factor model, has been tested. For this purpose, the mobility (mu) and retention factor (k) of a set of 10 phenolic compounds with different hydrophobicity and pKa values have been determined for several sodium dodecyl sulphate (SDS) concentrations and pH values, and fitted to the models. Results show that in general the retention factor model explains better the retention of ionisable solutes, although for hydrophilic compounds at low SDS concentration, mobility model can give better fits. The different drawbacks pointed out by several authors in relation to both models have been checked, and a deep evaluation of each one has been done. As a result we have observed that, while in the retention factor model the variation of k with pH and [SDS] always follows the same trend, the variation of mu with these variables mainly depends on the value of the binding constant of the neutral form of the solutes to the micelles, KHA(m), which plays a critical role in the fit of the mobility model. Also we provide rules and advices to set up the experimental conditions to apply each model to a particular solute.

Chromatography, Micellar Electrokinetic Capillary↗