Two-vector mechanics.

Abstract

The conventional orthodontic appliance is not without its limitations for certain types of tooth movements; in particular, if the appliance cannot access the area to elicit the type of force vector for a particular displacement. Examples of such movements are: space closure by translation, uprighting and intrusion of posterior teeth, intrusion with retraction and lingual root torque of anterior teeth. In this paper we describe a mathematical method to design an appliance system that overcomes these difficulties. This system includes two statically determined elements and allows for highly controlled force vector application point and direction. A clinical case of midline discrepancy is shown to demonstrate the clinical use and utility of this method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Fiorelli, B Melsen, C Modica. 2003. Two-vector mechanics.. https://pubmed.ncbi.nlm.nih.gov/14985798/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Maintenance of graft compression in the adult cervical spine.

It is generally advised that the graft inserted in adult cervical spine should be pre-loaded with a compressive force or that the screws are inserted in a divergent orientation, in order to maximise compression and the chance of graft incorporation (Truumees et al. in Spine 28:1097-1102, 2003). However, there is little evidence that a compressive force is maintained once the force applicator has been removed, or that the divergent screws enhance compression. This study compared the maintenance of applied pre-load force, across cervical spine graft, between standard anterior plating technique with pre-load and divergent screws and a novel plate technique, which allows its application prior to removal of the force applicator. Six intact adult cadaveric human cervical spines were exposed by standard surgical technique. A Casper type distracter was inserted across the disc space of interest, the disc was removed. In 14 experiments, following the disc removal, an autologous iliac crest bone graft was inserted under distraction, together with a strain gauge pressure transducer. A resting output from the transducer was recorded. The voltage output has a linear relationship with compressive force. A standardised compressive force was applied across the graft through the "Casper type" distracter/compressor (7.5 kg, torque). The pre-load compressive force was measured using a torque drill. Then two different procedures were used in order to compare the final applied strain on the bone graft. In eight experiments (procedure 1), the "Casper type" distracter/compressor was removed and a standard anterior cervical plate with four divergent screws was inserted. In six experiments (procedure 2), a novel plate design was inserted prior to removal of the distracter/compressor, which is not possible with the standard plate design. A final compressive force across the graft was measured. For the standard plate construct (procedure 1), the applied compression force is significantly greater than resting (SO/SC)--P=0.01, but the compression force is not maintained once the compressor is removed (SO/SR)--P=0.27. Final bone graft compression after plate insertion is not significantly different to the resting state (SO/SF)--P=0.16 (Wilcoxon's sign test for paired observation). Application of the plate tended to offload the graft; the final compressive force is 170+/-100% less than the resting force. None of the applied force was maintained (mean 9.5+/-8.8%). For the new plate (procedure 2), the end compressive force (SF) measured across the graft was greater than the resting force (SO) (P<0.001). Further, the novel plate application increased the compressive force on the graft by 712+/-484%. The final bone graft compression using a novel plate, which allows its application prior to removal of the force applicator, is significant (SO/SF)--P=0.01. Here, 77+/-10% of the applied pre-load was maintained. The difference between the plates is significant (P<0.001). Conclusions are as follows: (1) Applied pre-load is not maintained across a graft once the force applicator is removed. (2) Divergent screws with a plate do not compress graft and rather tend to offload it. (3) Compressive force may be maintained if the plate is applied prior to the force applicator removal.

Biomechanical Phenomena↗

A novel method of producing a repetitive dynamic signal to examine reliability and validity of gait analysis systems.

Gait dysfunction is a common functional complaint of clients who seek medical care. Gait dysfunction can be caused by musculoskeletal disorders such as osteoarthritis or fractures, or it can be caused by neuromuscular disorders such as multiple sclerosis or cerebrovascular accident. Decisions made by health care providers working with these clients could be enhanced by the availability of valid and reliable gait measurement. Valid and reliable gait measurement is possible with laboratory-based motion analysis systems, but these are not universally available. Several portable systems collect footfall data and provide a relatively inexpensive alternative to sophisticated motion analysis systems. However, data collected by these portable systems cannot be used with confidence because of the lack of verification of the validity and reliability of the data they collect about movement. This paper describes a novel method of examining test-retest reliability and concurrent validity that produces a signal with minimal variation. To produce repetitive distance and timing events, a cylindrical weight was rolled across the field of both the laboratory motion analysis system and the system to be evaluated. Measures of the weight's movement were taken simultaneously with both systems. A reference point was chosen to allow for comparison between the systems. The spatial measure that was compared between systems was the horizontal distance between successive repetitions of the reference point's vertical position. The temporal measure that was compared between systems was the time between successive repetitions of the reference point's vertical position. The method described in this paper provides a minimally variable repetitive signal that can be used to investigate concurrent validity of gait analysis systems.

Biomechanical Phenomena↗

A method for comparing manual muscle strength measurements with joint moments during walking.

This paper describes a protocol for dynamometer assisted manual muscle testing of the major muscle groups of the lower extremity and its application to 11 able-bodied children who also had conventional gait analysis to obtain joint kinetics. Data from the manual muscle testing was processed in such a way that the results for maximum muscle strength (grade 5) and resistance against gravity alone (grade 3) were presented in Nm/kg allowing direct comparison with conventional joint kinetics. The strength measurements of the hip muscles and the knee extensors were between two and three times the moments exerted during normal walking. Those of the knee flexors and dorsiflexors were about five times the joint moments. Measured plantarflexor strength was only just greater than the moment exerted during walking. These results, particularly those for the plantarflexors, question how valid it is to use measures of isometric muscle strength as indicators of muscle function during activity. The study also compares grade 3 muscle strength with both grade 5 strength and the maximum joint moments. For all muscle groups tested grade 3 muscle strength was less than the maximum moment exerted during normal walking. For the plantarflexors it was less than 1% of that moment. The study demonstrates that reliable isometric muscle testing is possible in able-bodied children but requires considerable care and is time consuming. More work is required to understand how measurements made in this way relate to how muscles function during activity.

Biomechanical Phenomena↗