PubMed Health⌕ Search

PubMed · 1501533

Motion artifact suppression: a review of post-processing techniques.

Abstract

Patient motion during data acquisition in magnetic resonance imaging causes artifacts in the reconstructed image, which for two-dimensional Fourier transform imaging techniques appear as blurring and ghost repetitions of the moving structures. While the problem with intra-view effects has been effectively addressed using gradient moment nulling techniques, there is no corresponding technique for inter-view effects with equal effectiveness and general applicability. A number of techniques have been proposed for correcting the inter-view effects, and these may be divided into those that minimise the corruption of the data, and those that post-process the data to restore the image. The techniques in the former category are briefly reviewed, then those in the latter category are examined in detail. These are analysed in terms of motion model, model parameter estimation, and data correction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Hedley, H Yan. 1992. Motion artifact suppression: a review of post-processing techniques.. https://doi.org/10.1016/0730-725x(92)90014-q

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗