PubMed Health⌕ Search

PubMed · 15034648

Endotracheal suctioning: from principles to practice.

Abstract

OBJECTIVE: This paper aims to highlight the physical principles of pressure and flow dynamics underlying endotracheal suctioning, to demonstrate these on a simple illustrative model and to discuss the clinical implications of these principles for paediatric practice. DESIGN: Prospective in vitro study. SETTING: Paediatric intensive care unit of a tertiary, academic hospital. MEASUREMENTS AND MAIN RESULTS: The peak pressure change (DeltaP) obtained in a "bag-in-box" model was recorded during suctioning, using different combinations of endotracheal tube (ETT) and catheter sizes, different suction pressures and techniques. Suction was also performed on three different consistencies of gelatine, using a range of suction catheter sizes and vacuum pressures. The mass of gelatine suctioned per second was calculated. A large DeltaP was measured when using neonatal-sized ETTs. There was a linear relationship (r=0,8, p<0.05) between DeltaP and the ratio of external catheter area to area difference (internal ETT area-external catheter area). Significantly greater DeltaP was measured when using a short versus long suction catheter ( p<0.001) and when applying suction for longer duration ( p<0,001) and with higher vacuum pressures ( p<0.05). The amount of mucus suctioned in a given time was related to catheter size, suction pressure and mucus density. CONCLUSION: Applied clinically, these results indicate that intrapulmonary pressure changes generated by the endotracheal suctioning of intubated neonates are likely to be considerable, possibly translating into loss of lung volume.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brenda M Morrow, Merle J Futter, Andrew C Argent. 2004-03-18. Endotracheal suctioning: from principles to practice.. https://doi.org/10.1007/s00134-004-2238-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune heparin-induced thrombocytopenia resulting from preceding exposure to heparin catheter flushes.

Immune heparin-induced thrombocytopenia (HIT) is a life-threatening adverse effect of heparin. It can result from any type of heparin exposure and by any route of administration; however only a few cases are reported after exposures to small quantities of heparin from catheter flushes. The major clinical problem associated with HIT is thrombosis. Early detection and institution of alternative, non-heparin anticoagulation are important. We report a patient with HIT associated with use of therapeutic-dose unfractionated heparin in whom immune sensitization to heparin was triggered by two 500-unit exposure to UFH associated with intravascular catheter flushing for antineoplastic chemotherapy in a patient with colon adenocarcinoma.

Catheterization↗