PubMed Health⌕ Search

PubMed · 15036442

Reference ballistic imaging database performance.

Abstract

Ballistic imaging databases allow law enforcement to link recovered cartridge cases to other crime scenes and to firearms. The success of these databases has led many to propose that all firearms in circulation be entered into a reference ballistic image database (RBID). To assess the performance of an RBID, we fired 4200 cartridge cases from 600 9mm Para Sig Sauer model P226 series pistols. Each pistol fired two Remington cartridges, one of which was imaged in the RBID, and five additional cartridges, consisting of Federal, Speer, Winchester, Wolf, and CCI brands. Randomly selected samples from the second series of Remington cartridge cases and from the five additional brands were then correlated against the RBID. Of the 32 cartridges of the same make correlated against the RBID, 72% ranked in the top 10 positions. Likewise, of the 160 cartridges of the five different brands correlated against the database, 21% ranked in the top 10 positions. Generally, the ranking position increased as the size of the RBID increased. We obtained similar results when we expanded the RBID to include firearms with the same class characteristics for breech face marks, firing pin impressions, and extractor marks. The results of our six queries against the RBID indicate that a reference ballistics image database of new guns is currently fraught with too many difficulties to be an effective and efficient law enforcement tool.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jan De Kinder, Frederic Tulleners, Hugues Thiebaut. 2004-03-10. Reference ballistic imaging database performance.. https://doi.org/10.1016/j.forsciint.2003.12.002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance of the FearID earprint identification system.

The Forensic Ear Identification (FearID) research project was started in order to study the strength of evidence of earprints found on crime scenes. For this purpose, a sample of earprints from 1229 donors over three countries was collected. From each donor three left and three right earprints were gathered. On the one hand, operators denoted contours of the earprints to facilitate segmentation of the images, on the other anthropological specialists denoted anatomically specific locations. On the basis of this, methods for automated classification were developed and used for training of a system that classifies pairs of prints as 'matching' or 'non-matching'. Comparing lab quality prints, the system has an equal error rate of 4%. Starting from a reference database containing two prints per ear, hitlist behaviour is such that in 90% of all query searches the best hit is in the top 0.1% of the list. The results become less favourable (equal error rate of 9%) for print/mark comparisons.

Databases, Factual↗

Normal limits of ejection fraction and volumes determined by gated SPECT in clinically normal patients without cardiac events: a study based on the J-ACCESS database.

PURPOSE: Quantitative gated single-photon emission computed tomography (SPECT) is known to have high accuracy and precision for measurement of the principal cardiac functional parameters. We hypothesised that normal values for EF and LV volumes may differ among nationalities, and that optimal threshold values specific to the study population are required. METHODS: Among 4,670 consecutively registered patients for a J-ACCESS (Japanese investigation regarding prognosis based on gated SPECT) study from 117 hospitals, a total of 268 (149 women, 119 men) were selected who had no baseline cardiac diseases and had experienced no cardiac events during the preceding 3-year period. A gated SPECT study was performed with 99mTc-tetrofosmin and analysed with Cedars Sinai Medical Center's quantitative gated SPECT (QGS) software. The results in respect of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV), and EDV, ESV and SV normalised by body surface area (EDVI, ESVI and SVI), were calculated and summarised to obtain normal limits. RESULTS: EF for women and men was 74 +/- 9% and 63 +/- 7%, respectively (p < 0.0001). EDV, ESV and SV were significantly smaller in women than in men. Based on multiple regressions for linear models, the primary and secondary predictors of EF, EDVI, ESVI were gender and age. By stepwise multiple regression analysis, a statistically significant third predictor for EDV, ESV, SV and SVI was body weight. No colinearity was found between age and body weight. Important factors for the studied Japanese population included a high incidence of small hearts in women and the relatively advanced age of the population (the mean age +/-SD was 64.1 +/- 10.0 years for women and 60.9 +/- 11.7 years for men). CONCLUSION: EF and volumes determined by gated SPECT with QGS were significantly affected by gender and age, with body weight as a third predictor for volumes. Moreover, the normal limits were so specific for the population studied that standards appropriate for the study in question should be utilised.

Databases, Factual↗