[Checking the precision of capnometers].

Abstract

Capnometry, i.e. measurement of CO2 concentration (cCO2, vol%) and calculation of the respective CO2 partial pressure (pCO2, mmHg), is simple to apply, but the user must understand its principles of operation in order to appreciate its power and its limitations. However, sidestream capnometers use to dry the humidified respired gas (37 degrees C, pH2O 47 mmHg) for methodological reasons, thus increasing pCO2 by ca. 6% which, in turn, requires correction. With infrared spectroscopy, overestimation of pCO2 in presence of N2O and underreporting of pCO2 in presence of O2 also require to be corrected. These require either knowledge of the respective gas concentrations (mainstream analyzers) or adequate (i.e. correct) measurement (some sidestream capnometers). Changes in barometric pressure (pB) must be also either known or be measured automatically. Evaluation of the precision of capnometers must therefore focus on, (1) the possible pH2O correction, (2) the possible effects exercised by O2 and N2O, and (3) the possible dependence on barometric pressure. Two mainstream (Capnolog D/Dräger; Sirecust 404-1/Siemens) and eight sidestream capnometers (AGM 1304/Brüel & Kjaer; SARAcap A. G. and SARA-trans/Biomedical Systems/Hellige; Capnomac and Normocap 200/Datex/Hoyer; CO2 Monitor/Dräger; Nellcor N-1000/Nellcor/Dräger; Multinex/Datascope) were investigated. Dry and humidified gases (37 degrees C) of defined composition in respect of CO2, O2, N2, N2O, and H2O, were used for evaluation. The results prove reproducibility of ca. =/- 1 mmHg for the 10 capnometers within the 30-50 mmHg pCO2 range.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Zander, F Mertzlufft. 1992. [Checking the precision of capnometers].. https://doi.org/10.1055/s-2007-1000250

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Perception of training needs and opportunities in advanced airway skills: a survey of British and Irish trainees.

BACKGROUND AND OBJECTIVE: We surveyed delegates at the Group of Anaesthetists in Training (UK) meeting to investigate evidence of a training-gap (number of fibreoptic intubations believed to bestow competence vs. number actually performed). METHODS: Questionnaires were distributed to and collected from delegates in person. Questions covered six areas, including experience of fibreoptic intubation and cricothyrotomy, fibreoptic intubation as a specialist skill and ethical issues. RESULTS: We received 221 replies (76%). All trainees believed competence to be achievable with 10 intubations (interquartile range (IQR) 10-20); the median number performed was 2 (IQR 0-4). This was statistically significant for the groups' senior house officers, 1st and 2nd year registrars and 3rd and 4th year registrars; P < 0.0001. Many final year trainees (12/20, 60%) also failed to achieve their competency target. Few trainees had seen or performed any cricothyrotomies (medians 0, IQRs 0-1 and 0-0). Most (195/208, 94%) believed that fibreoptic intubation was a core skill and 199/212 (94%) believed that all should be competent by completion of training. Ten percent (n = 208) felt it unethical to perform an awake training intubation with full consent and 10% believed it acceptable without explanation. Most (82.7%) would fibreoptically intubate an asleep patient (requiring intubation) without consent. CONCLUSION: Trainees reported a gap between their perception of competence and achievement in awake fibreoptic intubation. Simple and complex simulations and structured training programmes may help. Anaesthetists must address the ethics of clinical training in advanced airway management.

Anesthesiology↗