Baxter Aurora dialysis system.

Abstract

With the recent focus on the benefits of more frequent dialysis, the Baxter Aurora dialysis system provides maximum flexibility for therapy prescription, including short daily treatments, long nocturnal treatments, hemodialysis, hemofiltration, and online hemodiafiltration, all in a compact, reliable, easy to use system. A self-prompting touch screen user interface mounted on a movable arm provides for comfortable operation, whether sitting and standing. An automatic treatment setup mode facilitates easy treatment setup. Complex menus are eliminated by the use of a hardware key that automatically selects only the prescribed options during power up, eliminating all menus associated with nonprescribed functions and modalities. This prevents the user from becoming confused or accidentally altering the dialysis treatment. Prior to dialysis the instrument goes through an automatic self-test that confirms the operation of internal systems. The screen will dim when there is no action that the patient needs to attend to on the instrument. After dialysis, press the disinfect button and the instrument disinfects itself and shuts off. For patient safety, the "disinfect" menus are not available during dialysis. The instrument can also be programmed to automatically start and rinse at a set time. For remote treatment monitoring, the instrument connects to the Internet. The Aurora records information about the machine's technical status, providing a record of instrument history for easy servicing. The Aurora is a flexible platform that provides the desired renal therapy with ease of use and proper support for the hemodialysis patient when combined with Baxter's 24-hour infrastructure and support.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Thomas D Kelly. Baxter Aurora dialysis system.. https://doi.org/10.1111/j.0894-0959.2004.17215.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗