[Pneumothorax during nasal-CPAP: a predictable complication?].

Abstract

OBJECTIVE: Pneumothorax (PNX) is a relatively common complication of nasal-CPAP (N-CPAP). Aim of the study was to identify prognostic factors of its onset. METHODS: Seventy-seven newborns, admitted from January to December 2002 to the Neonatal Intensive Care Unit of Brescia, who were treated with N-CPAP with Infant Flow System as first intention, were included. Gestational age and birth weight were (mean +/- SD) 33.7 +/- 3.02 weeks and 2.047 +/- 684 grams, respectively. Infants were put on N-CPAP at 2.7 +/- 4.1 hours of life. The duration of treatment was 27.7 +/- 27.7 hours. RESULTS: Fifty-one neonates improved and N-CPAP was discontinued, 26 worsened and required intubation and mechanical ventilation. Eight of them developed PNX (10,3%). No significant differences were found among the three groups (improved, worsened without PNX and worsened with PNX) concerning mode of delivery, gestational age, birth weight and blood gases. The patients with PNX needed a FiO2 28% higher than the initial value after 12 hours of treatment, and 46% higher at 24 hours (p = 0,017). At diagnosis, FiO2 was 53,5% higher than the initial value (p = 0,005). CONCLUSION: A 40% increase of FiO2, during the first 24 hours of N-CPAP may represent an useful marker to identify the infants at high risk of developing a pneumothorax.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Migliori, A Campana, D Cattarelli, F Pontiggia, G Chirico. [Pneumothorax during nasal-CPAP: a predictable complication?].. https://pubmed.ncbi.nlm.nih.gov/15058833/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Review of oral appliances for treatment of sleep-disordered breathing.

Between 1982 and 2006, there were 89 distinct publications dealing with oral appliance therapy involving a total of 3,027 patients, which reported results of sleep studies performed with and without the appliance. These studies, which constitute a very heterogeneous group in terms of methodology and patient population, are reviewed and the results summarized. This review focused on the following outcomes: sleep apnea (i.e. reduction in the apnea/hypopnea index or respiratory disturbance index), ability of oral appliances to reduce snoring, effect of oral appliances on daytime function, comparison of oral appliances with other treatments (continuous positive airway pressure and surgery), side effects, dental changes (overbite and overjet), and long-term compliance. We found that the success rate, defined as the ability of the oral appliances to reduce apnea/hypopnea index to less than 10, is 54%. The response rate, defined as at least 50% reduction in the initial apnea/hypopnea index (although it still remained above 10), is 21%. When only the results of randomized, crossover, placebo-controlled studies are considered, the success and response rates are 50% and 14%, respectively. Snoring was reduced by 45%. In the studies comparing oral appliances to continuous positive airway pressure (CPAP) or to uvulopalatopharyngoplasty (UPPP), an appliance reduced initial AHI by 42%, CPAP reduced it by 75%, and UPPP by 30%. The majority of patients prefer using oral appliance than CPAP. Use of oral appliances improves daytime function somewhat; the Epworth sleepiness score (ESS) dropped from 11.2 to 7.8 in 854 patients. A summary of the follow-up compliance data shows that at 30 months, 56-68% of patients continue to use oral appliance. Side effects are relatively minor but frequent. The most common ones are excessive salivation and teeth discomfort. Efficacy and side effects depend on the type of appliance, degree of protrusion, vertical opening, and other settings. We conclude that oral appliances, although not as effective as CPAP in reducing sleep apnea, snoring, and improving daytime function, have a definite role in the treatment of snoring and sleep apnea.

Continuous Positive Airway Pressure↗

Lung mechanics at the bedside: make it simple.

PURPOSE OF REVIEW: The aim of this review is to describe ventilator-patient interaction, employing the equation of motion and the curves obtained by the ventilator. Practitioners confronted with mechanically ventilated patients every day in intensive care units should be able to sort out from all data available from modern ventilators those relevant for choosing a correct ventilatory strategy for each patient. RECENT FINDINGS: Early determination of patient-ventilator asynchrony, air-leaks and variation in respiratory parameters is important during mechanical ventilation. A correct evaluation of data, for patient safety and tailored ventilatory strategy becomes mandatory when non-invasive ventilation by helmet or mask is applied. SUMMARY: The equation of motion is described and dynamic and static respiratory mechanics are analysed to highlight all those data that can influence decision-making in setting mechanical or assisted ventilation in invasively and non-invasively ventilated patients.

Continuous Positive Airway Pressure↗