Computed tomographic colonography (virtual colonoscopy): a multicenter comparison with standard colonoscopy for detection of colorectal neoplasia.

Abstract

CONTEXT: Conventional colonoscopy is the best available method for detection of colorectal cancer; however, it is invasive and not without risk. Computed tomographic colonography (CTC), also known as virtual colonoscopy, has been reported to be reasonably accurate in the diagnosis of colorectal neoplasia in studies performed at expert centers. OBJECTIVE: To assess the accuracy of CTC in a large number of participants across multiple centers. DESIGN, SETTING, AND PARTICIPANTS: A nonrandomized, evaluator-blinded, noninferiority study design of 615 participants aged 50 years or older who were referred for routine, clinically indicated colonoscopy in 9 major hospital centers between April 17, 2000, and October 3, 2001. The CTC was performed by using multislice scanners immediately before standard colonoscopy; findings at colonoscopy were reported before and after segmental unblinding to the CTC results. MAIN OUTCOME MEASURES: The sensitivity and specificity of CTC and conventional colonoscopy in detecting participants with lesions sized at least 6 mm. Secondary outcomes included detection of all lesions, detection of advanced lesions, possible technical confounders, participant preferences, and evidence for increasing accuracy with experience. RESULTS: A total of 827 lesions were detected in 308 of 600 participants who underwent both procedures; 104 participants had lesions sized at least 6 mm. The sensitivity of CTC for detecting participants with 1 or more lesions sized at least 6 mm was 39.0% (95% confidence interval [CI], 29.6%-48.4%) and for lesions sized at least 10 mm, it was 55.0% (95% CI, 39.9%-70.0%). These results were significantly lower than those for conventional colonoscopy, with sensitivities of 99.0% (95% CI, 97.1%->99.9%) and 100%, respectively. A total of 496 participants were without any lesion sized at least 6 mm. The specificity of CTC and conventional colonoscopy for detecting participants without any lesion sized at least 6 mm was 90.5% (95% CI, 87.9%-93.1%) and 100%, respectively, and without lesions sized at least 10 mm, 96.0% (95% CI, 94.3%-97.6%) and 100%, respectively. Computed tomographic colonography missed 2 of 8 cancers. The accuracy of CTC varied considerably between centers and did not improve as the study progressed. Participants expressed no clear preference for either technique. CONCLUSIONS: Computed tomographic colonography by these methods is not yet ready for widespread clinical application. Techniques and training need to be improved.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peter B Cotton, Valerie L Durkalski, Benoit C Pineau, Yuko Y Palesch, Patrick D Mauldin, Brenda Hoffman, David J Vining, William C Small, John Affronti, Douglas Rex, Kenyon K Kopecky, Susan Ackerman, J Steven Burdick, Cecelia Brewington, Mary A Turner, Alvin Zfass, Andrew R Wright, Revathy B Iyer, Patrick Lynch, Michael V Sivak, Harold Butler. 2004-04-14. Computed tomographic colonography (virtual colonoscopy): a multicenter comparison with standard colonoscopy for detection of colorectal neoplasia.. https://doi.org/10.1001/jama.291.14.1713

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Magnetic resonance colonography vs computed tomography colonography for the diagnosis of colorectal cancer: an indirect comparison.

OBJECTIVE: The primary aim of this study was to use meta-regression techniques to compare the diagnostic accuracy of computed tomography colonography (CTC) and magnetic resonance colonography (MRC), compared with conventional colonoscopy for patients presenting with colorectal cancer (CRC). METHOD: Quantitative meta-analysis was performed using prospective studies reporting comparative data between CTC and MRC individually to conventional colonoscopy. Study quality was assessed and sensitivities, specificities, diagnostic odds ratios (DOR) were calculated. Summary receiver operating characteristic (SROC) curves and sensitivity analysis were utilized. Meta-regression was used to indirectly compare the two modalities following adjustment for patient and study characteristics. RESULTS: Overall sensitivity and specificity for CTC (0.96, 95% CI 0.92-0.99; 1.00, 95% CI 0.99-1.00 respectively) and MRC (0.91, 95% CI 0.79-0.97; 0.98, 95% CI 0.96-0.99 respectively) for the detection of CRC was similar. Meta-regression analysis showed no significant difference in the diagnostic accuracy of both modalities (beta=-0.64, P=0.37 and 95% CI of 0.12-2.39). Both tests showed high area under the SROC curve (CTC=0.99; MRC=0.98), with high DORs (CTC=1461.90, 95% CI 544.89-3922.30; MRC=576.41, 95% CI 135.00-2448.56). Factors that enhanced the overall accuracy of MRC were the use intravenous contrast, faecal tagging and exclusion of low-quality studies. No factors improved diagnostic accuracy from CTC except studies with more than 100 patients (AUC=1.00, DOR=2938.35, 95%CI 701.84-12 302.91). CONCLUSION: This meta-analysis suggested that CTC and MRC have similar diagnostic accuracy for detecting CRC. Study quality, size and intravenous/intra-luminal contrast agents affect diagnostic accuracies. For an exact comparison to be made, studies evaluating CTC, MRC and colonoscopy in the same patient cohort would be necessary.

Colonography, Computed Tomographic↗

Development of a synthetic phantom for the selection of optimal scanning parameters in CAD-CT colonography.

The aim of this paper is to present the development of a synthetic phantom that can be used for the selection of optimal scanning parameters in computed tomography (CT) colonography. In this paper we attempt to evaluate the influence of the main scanning parameters including slice thickness, reconstruction interval, field of view, table speed and radiation dose on the overall performance of a computer aided detection (CAD)-CTC system. From these parameters the radiation dose received a special attention, as the major problem associated with CTC is the patient exposure to significant levels of ionising radiation. To examine the influence of the scanning parameters we performed 51 CT scans where the spread of scanning parameters was divided into seven different protocols. A large number of experimental tests were performed and the results analysed. The results show that automatic polyp detection is feasible even in cases when the CAD-CTC system was applied to low dose CT data acquired with the following protocol: 13 mAs/rotation with collimation of 1.5 mm x 16 mm, slice thickness of 3.0mm, reconstruction interval of 1.5 mm, table speed of 30 mm per rotation. The CT phantom data acquired using this protocol was analysed by an automated CAD-CTC system and the experimental results indicate that our system identified all clinically significant polyps (i.e. larger than 5 mm).

Colonography, Computed Tomographic↗