PubMed Health⌕ Search

PubMed · 15086280

Calibration verification performance relates to proficiency testing performance.

Abstract

CONTEXT: Since 1988, the College of American Pathologists has been offering materials for calibration verification coupled with the surveys for linearity, called the linearity (LN) surveys. OBJECTIVE: To determine whether successful completion of the College of American Pathologists LN surveys provides a benefit in terms of improved proficiency testing (PT) performance. DESIGN: In this study, we used information from LN surveys LN1/2, LN3, and LN5 and from the PT surveys C, Z, and K administered and analyzed in the year 2000. For the PT data, we calculated 4 measures of performance: passing PT, results exceeding 2 SDs, sum of absolute SD intervals, and the absolute sum of SD intervals. For the LN data, we classified laboratories as participants versus nonparticipants in LN surveys and by whether or not LN survey performance was successful. RESULTS: LN enrollees had fewer unacceptable PT results than did nonenrollees. Additionally, for many analytes there was a significant positive association between LN performance and PT performance. CONCLUSIONS: For most analytes studied, there was strong evidence linking performance on PT surveys with performance on LN surveys. Eight of 13 analyses (62%) demonstrated improved performance with successful calibration verification.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Martin H Kroll, Patricia E Styer, Delmiro Anthony Vasquez. 2004. Calibration verification performance relates to proficiency testing performance.. https://doi.org/10.5858/2004-128-544-cvprtp

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Discrimination of normal, inflammatory, premalignant, and malignant oral tissue: a Raman spectroscopy study.

Optical spectroscopy methods are fast emerging as potential alternatives for early diagnosis of cancer. A Raman spectroscopy method for discrimination of normal and malignant oral tissues has been developed by us earlier. It is necessary to evaluate and establish the validity of the approach before it can be routinely used. In the present study, our Raman spectroscopy investigations are extended further to evaluate the efficacy of the technique to discriminate between normal, inflammatory, premalignant, and malignant conditions in oral tissue. Spectral profiles of normal, malignant, premalignant, and inflammatory conditions show pronounced differences between one another. Spectra of normal tissues can be attributed mainly to lipids whereas pathological tissue spectra are dominated by proteins. Principal components analysis (PCA) of the spectral data sets belonging to the four different categories showed that scores of factors differentiated between normal and all pathological conditions but gave only poor discrimination among the three pathological states. PCA combined with multiparameter limit tests allow match/mismatch criteria to be applied to test samples when pathologically certified calibration sets are available in each class. It is shown that by this method all the four tissue types could be discriminated and diagnosed correctly. The biochemical differences between normal and pathological conditions of oral tissue are also discussed from spectral differences of the different classes of spectra.

Calibration↗

Determination of rizatriptan in human plasma by liquid chromatographic-eletrospray tandem mass spectrometry: application to a pharmacokinetic study.

A sensitive liquid chromatographic-tandem mass spectrometry(LC-MS/MS) method was developed for the determination of rizatriptan in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax XDB C8 column (150 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an electrospray ionization interface. Zomitriptan was used as the internal standard. The method had a lower limit of quantitation of 50 pg/mL for rizatriptan, which showed more sensitivity and speed of analysis compared with reported methods. The within- and between-day precision was measured to be below 11.71% and accuracy between -5.87 and 0.86% for all quality control samples. This quantitation method was successfully applied to the evaluation of the pharmacokinetic profiles of rizatriptan after single oral administration of 5, 10 and 15 mg rizatriptan tablets to 10 healthy volunteers (five males and five females).

Calibration↗