PubMed Health⌕ Search

PubMed · 15098414

External validity, generalizability, and knowledge utilization.

Abstract

PURPOSE: To examine the concepts of external validity and generalizability, and explore strategies to strengthen generalizability of research findings, because of increasing demands for knowledge utilization in an evidence-based practice environment. FRAMEWORK: The concepts of external validity and generalizability are examined, considering theoretical aspects of external validity and conflicting demands for internal validity in research designs. Methodological approaches for controlling threats to external validity and strategies to enhance external validity and generalizability of findings are discussed. CONCLUSIONS: Generalizability of findings is not assured even if internal validity of a research study is addressed effectively through design. Strict controls to ensure internal validity can compromise generalizability. Researchers can and should use a variety of strategies to address issues of external validity and enhance generalizability of findings. Enhanced external validity and assessment of generalizability of findings can facilitate more appropriate use of research findings.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Linda Ferguson. 2004. External validity, generalizability, and knowledge utilization.. https://doi.org/10.1111/j.1547-5069.2004.04006.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Impact of misclassification of in vitro fertilisation in studies of folic acid and twinning: modelling using population based Swedish vital records.

OBJECTIVE: To determine whether failure to adequately adjust for a reported 40% misclassification of use of in vitro fertilisation (IVF) as reported in a Swedish study could have led to a false finding that folic acid increases dizygotic twinning. DESIGN: Modelling with population based data. SETTING: Swedish vital records for 1995-9. MAIN OUTCOME MEASURES: Rates of twinning calculated according to whether women used IVF to become pregnant. Estimated unadjusted and adjusted odds ratios of the association between use of folic acid and twinning by use of IVF. RESULTS: In 1995-9, Swedish women who used IVF had an almost 20 times the chance of having twins than women who did not use IVF (rate ratio 19.7, 95% confidence interval 18.7 to 20.6). In the absence of a true effect of folic acid, the use of a 40% misclassified surrogate variable to adjust for use of IVF would have resulted in a false finding that folic acid was associated with a more than twofold increase in twinning. CONCLUSION: Use of IVF is a strong confounder because it is associated with both use of folic acid and twinning. Even when misclassification of IVF was reduced to 5%, this bias persisted in the adjusted model. Using a 40% misclassified surrogate to adjust for IVF, as reported in the Swedish study, probably led to a false finding that folic acid increased dizygotic twinning.

Data Collection↗

Evaluation of exhalation valves.

Certification tests currently employed by some industrialized nations to certify respirators require that when challenged with air flow at a constant suction head of 25 mmH2O, the leakage into the facepiece from the exhalation valve(s) should not exceed 30 ml min(-1). However, the test alone might not reflect the leakage rate under different levels of vacuum. To study the characteristics of leakage through exhalation valves, a leakage meter was built to measure the leakage rate of four brands of exhalation valves. Seven valves of each brand were tested for leakage rate at pressure drops ranging from 15 to 45 mmH2O (or extended to 75 mmH2O for some valves). Two types of leaks, i.e. fiber insertion and arch dent on the valve seat, were used to investigate the effect of leak shape on the characteristic leak flow as a function of pressure drop. A leakage data point represented a mean value of five measurements. The results showed that the leakage rate could increase or decrease with increasing pressure drop inside the respirators, indicating that the current method of conducting leakage tests, at a constant suction head of 25 mmH2O, does not guarantee better protection than when the respirators are used at a lower suction head. Moreover, based on the sample valves tested in this study, it was found that valve leakage was mostly caused by defects in the valve seats. Both fiber-insertion and arch-dent leaks had either increasing or decreasing characteristic curves, depending on the size of the leak and the material of the valve membrane.

Data Collection↗

Survey of computed tomography techniques and absorbed dose in Italian hospitals: a comparison between two methods to estimate the dose-length product and the effective dose and to verify fulfilment of the diagnostic reference levels.

The aim of this study was the production of the first Italian survey of radiation dose in computed tomography (CT) prior to the widespread adoption of multislice CT, in order to have a reference point to facilitate later investigation of dose exposure changes brought by this new CT modality. The collected dose data were compared with diagnostic reference levels (DRLs). The agreement between experimental dose evaluation and Monte Carlo (MC) simulations was investigated. The survey was carried out in 29 Italian hospitals, covered 48 CT scanners and 232 examinations. The dose-length product (DLP) and effective dose (E) values were estimated based on MC simulations for seven clinical protocols using the CT-Dose program. Statistical analysis showed a significant difference (p<0.01) in the DLP between the two methods, with MC values being greater than the experimental ones. For E, the MC values were greater in routine head (8.2%), cervical spine (2.7%) and lumbar spine (2.9%) studies. The weighted CT dose index, the DLP and E were always below the DRLs set by the European Community. This dose survey gives a good but incomplete picture of the Italian CT dose situation and may be useful as a reference baseline for defining clinical multislice protocols in the near future.

Data Collection↗