PubMed Health⌕ Search

PubMed · 15101341

Hip replacement. Less invasive procedures.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

2004. Hip replacement. Less invasive procedures.. https://pubmed.ncbi.nlm.nih.gov/15101341/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In vivo behavior of acrylic bone cement in total hip arthroplasty.

Polymethylmethacrylate (PMMA) bone cement serves as the primary fixation material between bone and the prosthetic component in cemented total hip arthroplasty. In vivo degradation of bone cement may lead to a decrease in mechanical properties of PMMA and result in aseptic loosening. However, other factors such as porosity and location of the cement relative to the bone implant interface may also contribute to mechanical behavior in vivo. This study investigated the mechanical properties of Simplex cement retrieved from 43 patients undergoing revision total hip arthroplasty. The time in vivo was between 1 month and 27 years. The variables studied included fracture toughness (KIC), porosity, molecular weight, time in vivo of the cement, and relative in vivo location of the cement with respect to the implant and bone. KIC did not correlate with time in vivo of the samples or with molecular weight. This suggests that time in vivo may not be the limiting factor in the mechanical integrity of the bone cement, A significant and inverse relationship was found between porosity and KIC. This implies that porosity is the most important factor in the mechanical behavior of bone cement during in vivo use.

Arthroplasty, Replacement, Hip↗

Three-dimensional computer-aided design based design sensitivity analysis and shape optimization of the stem using adaptive p-method.

The number of stem designs for total hip arthroplasty is increasing, and occasionally design changes have yielded unexpected clinical results. At present, we are not able to clearly identify which parameter of the stem is most important, and the optimum value of many parameters. The goals of this study were to identify which parameter is most important, to understand the effect of design change, and to find the optimum stem shape. For this purpose, we used adaptive p-method together with three-dimensional computer-aided design software program for the design sensitivity analysis (DSA) and shape optimization of the stem. The results suggested that increasing the lateral and medial width of the distal cross-section together with decreasing the medial-lateral width and the medial radius of the distal cross-section from the default value would lead to a decrease in the largest maximum principal stress of the distal cement. The medial width of middle cross-section, however, was not so simple. The result of DSA suggested that decreasing this parameter from the default value decreased the stress in the distal cement, but the optimum shape was obtained by increasing this parameter. The method used in this study will assist our engineers and surgeons in the process of modifying and optimizing the stem design.

Arthroplasty, Replacement, Hip↗