PubMed Health⌕ Search

PubMed · 15139233

A selective, fluorescent sensor for Zn2+.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yi Chen, De X Zeng. 2004-04-19. A selective, fluorescent sensor for Zn2+.. https://doi.org/10.1002/cphc.200301021

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A sensitive probe for the detection of Zn(II) by time-resolved fluorescence.

A new, highly sensitive fluorescent sensor for Zn(II) ion (a tris(2-pyridylmethyl)amine derivative) shows very strong binding and Zn(II) concentration-dependent biexponential time-resolved fluorescence (TRF) decay profiles that can be used for ratiometric estimates of Zn(II) concentrations. The ligand-metal complexes were characterized in solution by spectroscopic techniques and in the solid state by X-ray crystallography. The TRF studies revealed that the sensor aggregates in the absence of Zn(II) in a ligand concentration-dependent manner, a complication that is discerned by TRF but not by steady-state fluorescence ratiometric sensing techniques. It is shown that the same TRF methods are highly useful for monitoring Zn(II) concentrations in A549 epithelial lung cells in vitro and that the results were consistent with those in solution.

Cations, Divalent↗

Removal of Cr(VI) from Cr-contaminated groundwater through electrochemical addition of Fe(II).

The conventional chemical reduction-precipitation technique in the removal of Cr(VI) from contaminated groundwater involves a two-step process whereby Cr(VI) is first reduced to Cr(III) at an acidic pH by a reducing agent and in a subsequent step, Cr(III) is precipitated as insoluble hydroxide at an alkaline pH. In a variation of this method, Fe(II) is added electrochemically to the Cr(VI) containing water. From a pure iron electrode, Fe(2+) ions are released into the solution and bring forth the reduction of Cr(VI). At the cathode, H(2)O is reduced whereby the OH(-) ions entering the solution keep the pH of the solution in the alkaline range. This latter fact greatly facilitates simultaneous reduction of Cr(VI) to Cr(III) and co-precipitation of hydroxides of trivalent Cr and Fe. On the basis of a set of experimental data, it is shown that this process is both thermodynamically and kinetically efficient, meaning, with the electrochemical method, rapid and nearly complete removal of Cr(VI) from a groundwater source with both high and low levels of Cr-contamination can be achieved. These factors make the electrochemical process superior to the conventional chemical process in remediation of Cr-contaminated groundwater.

Cations, Divalent↗

Selective Hg(II) detection in aqueous solution with thiol derivatized fluoresceins.

The syntheses and photophysical properties of mercury sensors 2 and 3 (MS2 and MS3), two asymmetrically derivatized fluorescein-based dyes designed for Hg(II) detection, are described. These sensors each contain a single pyridyl-amine-thiol metal-binding moiety, form 1:1 complexes with Hg(II), and exhibit selectivity for Hg(II) over other Group 12 metals, alkali and alkaline earth metals, and most divalent first-row transition metals. Both dyes display superior brightness (Phi x epsilon) and fluorescence enhancement following Hg(II) coordination in aqueous solution. At neutral pH, the fluorescence turn-on derives from greater brightness due to increased molar absorptivity. At higher pH, photoinduced electron transfer quenching of the free dye is enhanced, and the Hg(II)-induced turn-on also benefits from alleviation of this pathway. MS2 can detect ppb levels of Hg(II) in aqueous solution, demonstrating its ability to identify environmentally relevant concentrations of Hg(II).

Cations, Divalent↗