Designing optically tracked instruments for image-guided surgery.

Abstract

Most image-guided surgery (IGS) systems track the positions of surgical instruments in the physical space occupied by the patient. This task is commonly performed using an optical tracking system that determines the positions of fiducial markers such as infrared-emitting diodes or retroreflective spheres that are attached to the instrument. Instrument tracking error is an important component of the overall IGS system error. This paper is concerned with the effect of fiducial marker configuration (number and spatial distribution) on tip position tracking error. Statistically expected tip position tracking error is calculated by applying results from the point-based registration error theory developed by Fitzpatrick et al. Tracking error depends not only on the error in localizing the fiducials, which is the error value generally provided by manufacturers of optical tracking systems, but also on the number and spatial distribution of the tracking fiducials and the position of the instrument tip relative to the fiducials. The theory is extended in two ways. First, a formula is derived for the special case in which the fiducials and the tip are collinear. Second, the theory is extended for the case in which there is a composition of transformations, as is the situation for tracking an instrument relative to a coordinate reference frame (i.e., a set of fiducials attached to the patient). The derivation reveals that the previous theory may be applied independently to the two transformations; the resulting independent components of tracking error add in quadrature to give the overall tracking error. The theoretical results are verified with numerical simulations and experimental measurements. The results in this paper may be useful for the design of optically tracked instruments for image-guided surgery; this is illustrated with several examples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jay B West, Calvin R Maurer. 2004. Designing optically tracked instruments for image-guided surgery.. https://doi.org/10.1109/tmi.2004.825614

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimization of a jet-propelled particle injection system for the uniform transdermal delivery of drug/vaccine.

A jet-propelled particle injection system, the biolistics, has been developed and employed to accelerate micro-particles for transdermal drug delivery. We have examined a prototype biolistic device employing a converging-diverging supersonic nozzle (CDSN), and found that the micro-particles were delivered with a wide velocity range (200-800 m/s) and spatial distribution. To provide a controllable system for transdermal drug delivery, we present a contoured shock-tube (CST) concept and its embodiment device. The CST configuration utilizes a quasi-steady, quasi-one dimensional and shock-free supersonic flow to deliver the micro-particles with an almost uniform velocity (the mean velocity and the standard deviation, 699 +/- 4.7 m/s) and spatial distribution. The transient gas and particle dynamics in both prototype devices are interrogated with the validated computational fluid dynamics (CFD) approach. The predicted results for static pressure and Mach number histories, gas flow structures, particle velocity distributions and gas-particle interactions are presented and interpreted. The implications for clinical uses are discussed.

Computer-Aided Design↗

A stand-alone peristaltic micropump based on piezoelectric actuation.

Despite significant efforts to develop micropumps, cumbersome driving equipment means that the design of portable micropumps remains a challenge. This study presents a stand-alone micropump system, which includes a peristaltic micropump based on piezoelectric actuation and a driving circuit. This battery-based driving circuit comprises a 12 V battery, an ATmega 8535 microprocessor, a 12 V-to-180 V DC to DC converter using transformerless technology, three differential amplifiers, an IC 7805, a phase controller, an A/D converter, a keyboard and an LCD module. The system can produce step-function signals with voltages of up to 228 V(pp) and frequencies ranging from 10 Hz to 100 kHz, as the inputs for the pump. It is portable and programmable with the package size of 22 x 12.8 x 9 cm. Additionally, this proposed system is used to design the driving signals of the pump which are 3-, 4, and 6-phase actuation sequences. This work performs the circuit testing and fluid pumping, and demonstrates the effects of actuation sequences on pump performance in terms of the dynamic behavior of the diaphragm, flow rates, back pressure and power consumption of the system. The experimental results show that the pump excited by the 6-phase sequence results in better performance compared with the 3- and 4-phase sequences, and produces a maximum flow rate of 36.8 microl/min and a maximum back pressure of 520 Pa with deionized water at 100 V (pp) and 700 Hz.

Computer-Aided Design↗

Novel transmit protection scheme for ultrasound systems.

The problem of protecting or isolating extremely sensitive receive circuitry from high-voltage transmit circuitry is commonly addressed through the use of diode bridges, transformers, or high-voltage switches, which prove to be prohibitively expensive, bulky, and power consuming for use in portable, low-cost, battery-powered systems. These approaches also compound the interconnect difficulties associated with two-dimensional (2-D) transducer arrays. In this paper we present a novel transmit protection scheme that allows compact MOSFET shunting devices to be brought on-chip within each receive channel implemented in a standard CMOS integrated circuit process. During transmit, the high voltage transmit pulse is driven onto the common connection of the transducer array and the on-chip MOSFET devices shunt the current to ground. During receive, these devices are turned off, the common connection of the transducer array is shunted to ground, and the received echo can be detected as usual. The transmit protection scheme was experimentally shown to shunt a 16 mA peak current resulting from the equivalent of a 100-V, 25-ns-risetime transmit pulse through a 4 pF transducer element. The scheme was also incorporated into a prototype 1024-channel, low-cost, ultrasound system successfully used to form pulse echo images.

Computer-Aided Design↗