Substrate capacity considerations in developing kinase assays.

Abstract

In developing a screening assay for a serine/threonine kinase, we evaluated various formats of an in-plate enzyme-linked immunosorbent assay (ELISA), as well as solution-phase kinase assays using either ELISA or AlphaScreen detection. Substrate was available both as a biotinylated 15-residue peptide and as a 25-residue peptide containing the same sequence expressed as a glutathione S-transferase fusion protein. When increasing concentrations of either of these substrates were coated directly onto ELISA plates, the rates of the kinase reactions progressively increased. In contrast, when the biotin-peptide was captured onto NeutrAvidin-coated plates, the finite peptide binding capacity of the plates limited the amount of substrate that could be incorporated into the assay system and thereby limited the rate of the reaction at a given kinase concentration. Solution-phase kinase reactions can tolerate high substrate concentrations; however, analysis of kinase reaction samples containing biotin-peptide concentrations higher than the binding capacity of NeutrAvidin-coated plates resulted in an inability to detect differences between reactions run at different substrate concentrations. For AlphaScreen detection following solution-phase kinase reactions, limitations in the binding capacity of the donor and acceptor beads caused loss of signal for substrate concentrations above the maximum binding capacity. Overall, the solution-phase assays required significantly more kinase than the in-plate assays (1-4 microg/ml versus <100 ng/ml, respectively). These studies demonstrate that the amount of substrate that can be incorporated into an assay system substantially affects the rate of the kinase reaction and therefore the amount of kinase required for the assay.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Laura E DeForge, Andrea G Cochran, Sherry H Yeh, Brian S Robinson, Karen L Billeci, Wai Lee T Wong. 2004. Substrate capacity considerations in developing kinase assays.. https://doi.org/10.1089/154065804323056477

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Recombinant truncated nucleocapsid protein as antigen in a novel immunoglobulin M capture enzyme-linked immunosorbent assay for diagnosis of severe acute respiratory syndrome coronavirus infection.

We report the development of an immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) for severe acute respiratory syndrome coronavirus (SARS-CoV) by using recombinant truncated SARS-CoV nucleocapsid protein as the antigen. The newly developed MAC-ELISA had a specificity and sensitivity of 100% as evaluated by using sera from healthy volunteers and patients with laboratory-confirmed SARS. Using serial serum samples collected from SARS patients, the times to seroconversion were determined by IgM antibody detection after SARS-CoV infection. The median time to seroconversion detection was 8 days (range, 5 to 17 days) after disease onset, and the seroconversion rates after the onset of illness were 33% by the first week, 97% by the second week, and 100% by the third week. Compared with the results of our previous report on the detection of IgG, the median seroconversion time by IgM detection was 3 days earlier and the seroconversion rate by the second week after the illness for IgM was significantly higher than by IgG assay. Our results indicating that the IgM response appears earlier than IgG after SARS-CoV infection in consistent with those for other pathogens. Our newly developed MAC-ELISA system offers a new alternative for the confirmation of SARS-CoV infection.

Enzyme-Linked Immunosorbent Assay↗

Perfusion with lipopolysaccharide differently affects the secretion of tumor necrosis factor-alpha and interleukin-6 by term and preterm human placenta.

This study has compared the functional capacity of term and preterm placentas in terms of production of pro-inflammatory cytokines in a perfusion system reflecting their ability to react to inflammatory agents, such as lipopolysaccharide (LPS), mimicking the situation of chorioamnionitis. We have demonstrated that term placentas secrete higher levels of tumor necrosis factor (TNF)-alpha compared with preterm placentas. Moreover, TNF-alpha secretion was significantly higher after exposure to LPS in the maternal and fetal sides of term placentas. In contrast, in preterm placentas, only the fetal side responded with a significant increase in secretion of TNF-alpha after exposure to LPS. The maternal side of term placentas secreted significantly higher amounts of interleukin (IL)-6 compared with preterm placentas. Exposure to LPS significantly decreased IL-6 secretion from the maternal side in both term and preterm placentas. Moreover, the fetal side of term placentas secreted significantly lower amounts of IL-6 compared with preterm placentas. In summary, this study has indicated that term and preterm placental tissues have a differing responsiveness to LPS stimulation, with term placentas disposed to a higher TNF-alpha:IL-6 ratio. Release of cytokines into fetal circulation is less than into the maternal side. However, TNF-alpha is released into fetal circulation after LPS stimulation and this may be relevant to the etiology of chorioamnionitis.

Enzyme-Linked Immunosorbent Assay↗