PubMed Health⌕ Search

PubMed · 15167124

A leak quantification method using sulfur hexafluoride as tracer gas.

Abstract

Filter holders and continuous air monitors are used extensively in the nuclear industry. It is important to minimize leakage in these devices, and, in recognition of this consideration, a limit on leakage for sampling systems is specified in; however, the protocol given in the standard is really germane to measurement of significant leakage, e.g., several percent of the sampling flow rate. In the present study, we developed a technique for quantifying leakage and used that approach to measure the sealing integrity of a continuous air monitor and two kinds of filter holders. The methodology involves use of sulfur hexafluoride as a tracer gas with the device being tested operated under dynamic flow conditions. The leak rates in these devices were determined in the pressure range from 2.49 kPa (10 inches H2O) vacuum to 2.49 kPa (10 inches H2O) pressure at a flow rate of 56.6 L min-1 (2 cfm). For the two filter holders, the leak rates were less than 0.007% of the nominal flow rate. The leak rate in the continuous air monitors was less than 0.2% of the nominal flow rate. These values are well within the limit prescribed in the ANSI standard, which is 5% of the nominal flow rate. We suggest that the limit listed in the ANSI standard should be reconsidered as lower values can be achieved, and the methodology presented herein can be used to quantify lower leakage values in sample collectors and analyzers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Vishnu Karthik, Andrew R McFarland. 2004. A leak quantification method using sulfur hexafluoride as tracer gas.. https://doi.org/10.1097/00004032-200406000-00006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Exposure to mercury in the mine of Almaden.

OBJECTIVES: To describe the process for obtaining mercury and the historical exposure of Almadén miners to mercury. METHODS: Information on every workplace and historical data on production, technological changes in the productive process and biological and environmental values of mercury was collected. A job-exposure matrix was built with these values and the exposure to inorganic mercury was estimated quantitatively as mug/l of urine mercury. A cumulative exposure index was calculated for every worker by adding the estimates for every year in the different workplaces. RESULTS: In the mine, the highest exposures occurred during drilling, with values up to 2.26 mg/m3 in air, 2194 microg/l in urine and 374 microg/l in blood. Furnace operation and cleaning were the tasks with the highest values in metallurgy, peaking up to 3.37 mg/m3. The filling of bottles with mercury by free fall gave values within a range of 1.13-2.43 mg/m3 in air; these values dropped to 0.32-0.83 mg/m3 after introducing a new ventilation system. The toxicity effects of high doses of inorganic mercury on the central nervous and urinary systems have been known for decades. CONCLUSIONS: The exposure of the workers in Almadén mines to mercury has been very high. The extremely high content cinnabar ore of the mine explains the increased concentrations of mercury in air at the work places. This, together with inadequate working conditions, explains the high mercury levels found in blood and urine during the study period.

Air Pollutants, Occupational↗

Influence of start-up on PCDD/F emission of incinerators.

This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.

Air Pollutants, Occupational↗