PubMed Health⌕ Search

PubMed · 15172075

Automatic screening in postmortem toxicology.

Abstract

The systematic analysis of postmortem samples is one of the most challenging tasks in forensic toxicology. For determining cause of death, analysis of different tissues can be indispensable. Automation of these analyses would increase reproducibility and therefore lead to more reliable and comparable results. Recent developments in analytical toxicology and the availability of automation devices for various analytical stages, such as sampling, preliminary testing, sample extraction, chromatographic separation, identification, and data processing are examined and discussed. At present only parts of the analytical procedure have been automated-however, the goal should be the integration of these parts into a single, continuous process. Currently, only one "fully-automated" procedure for the comprehensive screening of blood and urine (excluding sample pretreatment, which remains separate) has been published. But it can be expected that automation of analytical procedures in forensic toxicology will indeed progress, even with regard to the very complex screening of postmortem samples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Stimpfl, W Vycudilik. 2004-06-10. Automatic screening in postmortem toxicology.. https://doi.org/10.1016/j.forsciint.2004.02.014

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Windows of detection of lorazepam in urine, oral fluid and hair, with a special focus on drug-facilitated crimes.

The purported lowering of sex opposition, coupled with a possible abrupt unconsciousness-inducing effect and ease of administration in spiked drinks have resulted in the use of hypnotics in cases of drug-facilitated offense. Among these compounds, lorazepam possesses amnesic properties and can impair an individual rapidly. The chances to detect this substance increase if the most sensitive methods are used and if the biological fluid which allows the longest possible detection time is available. In order to document the window of detection of lorazepam, we have orally administered 2.5 mg of the drug to three volunteers and collected oral fluid (n = l) over 8 h, urine (n = 2) over 144 h and hair (n = 3) 4 weeks after exposure. Lorazepam was analyzed by LC-MS/MS after alkalinisation (to pH 8.4 with phosphate buffer) and extraction by dichloromethane/diethyl ether in presence of diazepam-d5, used as internal standard. Reversed-phase separation on a XTerra C18 column was achieved in 12 min, under gradient conditions. Molecular ions (m/z 321 and 290 for lorazepam and the IS, respectively) were selected in Ql and the corresponding daughter ions (m/z 303 and 275 for lorazepam and m/z 154 and 198 for the IS) were detected in Q3 after collision with argon. Urine tested positive for lorazepam over 144 h (2-4 ng/ml), with a peak detected after 24 h exposure (411-880 ng/ml). Oral fluid tested positive for lorazepam over 8 h (0.7 ng/ml). Despite a limit of quantitation at 1 pg/mg, we were unable to detect a single lorazepam dose in hair, contrarily to most other benzodiazepines that are detectable. Therefore, in case of drug-facilitated crimes involving lorazepam, urine appears as the best specimen to document exposure, particularly if LC-MS/MS is used.

Chromatography, Liquid↗

Characterizing complex peptide mixtures using a multi-dimensional liquid chromatography-mass spectrometry system: Saccharomyces cerevisiae as a model system.

A rugged, reproducible, multi-dimensional LC-MS system was developed to identify and characterize proteins involved in protein-protein interactions and/or protein complexes. Our objective was to optimize chromatographic parameters for complex protein mixture analyses using automated peptide sequence recognition as an analytical end-point. The chromatographic system uses orthogonal separation mechanisms by employing strong cation exchange (SCX) in the first dimension and reversed phase (RP) in the second dimension. The system is fully automated and sufficiently robust to handle direct injections of protein digests. This system incorporates a streamlined post analysis results comparison, called DBParser, which permitted comprehensive evaluation of sample loading and chromatographic conditions to optimize the performance and reproducibility. Peptides obtained from trypsin digestion of a yeast soluble extract provided an open-ended model system containing a wide variety and dynamic range of components. Conditions are described that resulted in an average (n = 4) of 1489 unique peptide identifications, corresponding to 459 non-redundant protein sequence database records (SDRs) in the 20 microg soluble fraction digest.

Chromatography, Liquid↗