An improved thin-layer chromatography/mass spectrometry coupling using a surface sampling probe electrospray ion trap system.

Abstract

A combined surface sampling probe/electrospray emitter coupled with an ion trap mass spectrometer was used for the direct read out of unmodified reversed-phase C18 thin-layer chromatography (TLC) plates. The operation of the surface sampling electrospray ionization interface in positive and negative ionization modes was demonstrated through the direct analysis of TLC plates on which a commercial test mix comprised of four dye compounds viz., rhodamine B, fluorescein, naphthol blue black, and fast green FCF, and an extract of the caffeine-containing plant Ilex vomitoria, were spotted and developed. Acquisition of full-scan mass spectra and automated collection of MS/MS product ion spectra while scanning a development lane along the surface of a TLC plate demonstrated the advantages of using an ion trap in this combination. Details of the sampling system, benefits of analyzing a developed lane in both positive ion and negative ion modes, levels of detection while surface scanning, surface scan speed effects, and the utility of three-dimensional data display, are also discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael J Ford, Gary J Van Berkel. 2004. An improved thin-layer chromatography/mass spectrometry coupling using a surface sampling probe electrospray ion trap system.. https://doi.org/10.1002/rcm.1486

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Low-temperature inhibition of the activated sludge process by an industrial discharge containing the azo dye acid black 1.

A municipal wastewater treatment plant (WWTP) receiving industrial dyeing discharge containing acid black 1 (AB1) failed to meet NH(3) and BOD(5) discharge limits, especially for NH(3) during the winter. Dyeing discharge was combined with domestic sewage in volumetric ratios reflecting the range received by the WWTP and fed to sequencing batch reactors at 22 and 7 degrees C. Analysis of the various nitrogen species revealed complete nitrification failure at 7 degrees C with more rapid nitrification failure as the dye concentration increased. Slight nitrification inhibition occurred at 22 degrees C: NH(3) removal decreased from 99.9% for the control compared to only 97.0% removal with dye addition. Dye-bearing wastewater also reduced COD removal by half at 7 degrees C and by one-fifth at 22 degrees C, and increased effluent TSS nearly three-fold at 7 degrees C. Activated sludge quality at 7 degrees C deteriorated after exposure to AB1, as indicated by excessive foaming and the presence of filamentous bacteria and by a decrease in endogenous and exogenous oxygen uptake. Decreasing AB1 loading resulted in partial activated sludge recovery. Eliminating the dye-bearing discharge to the full-scale WWTP led to improved performance bringing the WWTP into compliance with discharge limits.

Amido Black↗

Detection of phosphoproteins on electroblot membranes using a small-molecule organic fluorophore.

A new formulation of the small-molecule organic fluorophore, Pro-Q Diamond dye, has been developed that permits rapid and simple detection of phosphoproteins directly on polyvinylidene difluoride (PVDF) or nitrocellulose membranes (electroblots). Protein samples are first separated by electrophoresis and then electroblotted to membranes, stained and destained, in an analogous manner as typically performed with Amido Black or Ponceau S dye staining of total protein profiles. After staining, blots are imaged using any of a variety of laser-based gel scanners, xenon-arc lamp-based gel scanners or charge-coupled device (CCD) camera-based imaging devices equipped with UV trans- or epi-illumination. The uncomplicated and reliable staining protocol delivers results in as little as 1 h and the limit of detection for the stain is typically 2-4 ng of phosphoprotein with a linear dynamic range of approximately 15-fold. Compared with traditional radiolabeling and antibody-based approaches, the new method offers significant advantages, including avoidance of radioactivity, no need for expensive antibodies, no requirement for blocking unoccupied sites on the membrane with protein or detergent solutions, no sequence context-specific binding to phosphorylated amino acid residues and the ability to analyze the native, steady-state phosphorylation of proteins obtained directly from tissue specimens or body fluids. Pro-Q Diamond dye binds directly and exclusively to the phosphate moiety, allowing it to detect the broadest spectrum of phosphorylated proteins possible. The stain binds noncovalently to phosphoproteins and is thus fully compatible with matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) or Edman sequencing. The blot stain is also compatible with standard colorimetric, fluorogenic, and chemiluminescent detection techniques employed in immunoblotting.

Amido Black↗