Time-resolved confocal fluorescence imaging and spectrocopy system with single molecule sensitivity and sub-micrometer resolution.

Abstract

We present novel technical features and results from a two channel confocal fluorescence lifetime microscope, which allows to efficiently investigate fluorescence dynamics down to the single molecule level. The MicroTime 200 time-resolved fluorescence microscope offers a multicolor excitation where different picosecond diode lasers are used. For imaging and positioning purposes we utilize a compact Piezo scanner which allows, due to a novel scanning algorithm and synchronisation technique, a superior movement and positioning accuracy. The data acquisition is completely based on time-correlated single photon counting, where every photon is detected and stored individually with its specific timing information (Time-Tagged Time-Resolved mode). This multiparameter data acquisition scheme offers the opportunity to analyse the parameter dependencies in a multitude of different ways. Standard intensity analysis can be used to reconstruct 2D-images or the temporal evolution (time trace) of the fluorescence of a single spot. The information from the two distinct detector channels additionally allows to investigate the polarisation of the emitted light or its spectral composition, for example for analysis of Fluorescence Resonance Energy Transfer (FRET). The timing information down to a picosecond scale offers the possibility not only to reconstruct fluorescence decay constants of each pixel for the purpose of Fluorescence Lifetime Imaging (FLIM) but also to analyze the fluorescence fluctuation correlation function of any single spot of interest. The flexible multichannel detector scheme enables in this case also a cross-correlation between spectrally separated parts of the emission light, or even identical parts of the fluorescence to eliminate detector artifacts. The photon arrival coincidence analysis can also be expanded in the sub-ns range to study fluorescence antibunching in the fluorescence emission of single molecules. The ability of combining these different pieces of temporal information allows the construction of extremely powerful analysis methods and assays. We demonstrate a variety of these capabilities with results obtained from fluorescently labeled latex beads, biological samples, and single molecules excited in the blue or red wavelength region.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Wahl, F Koberling, M Patting, H Rahn, R Erdmann. 2004. Time-resolved confocal fluorescence imaging and spectrocopy system with single molecule sensitivity and sub-micrometer resolution.. https://doi.org/10.2174/1389201043376841

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗