PubMed Health⌕ Search

PubMed · 15191102

Threshold selection in virtual bronchoscopy: phantom study and clinical implications.

Abstract

PURPOSE: To investigate the effect of the threshold selection on the apparent diameter of a virtual bronchus and the virtual wall morphology and to examine the parameters that can affect the selection of the appropriate threshold for virtual bronchoscopy with single slice computed tomography. MATERIAL AND METHODS: A bronchial phantom containing plastic tubes simulating the airways of the tracheobronchial tree was constructed. The diameters of the virtual images of these tubes were measured using various thresholds for two different materials surrounding the tubes: air and water. These measurements were correlated with the density in HU of the walls. Furthermore, data from 20 virtual bronchoscopies in patients were retrospectively analyzed in the same way. RESULTS: The diameter of a virtual bronchus is strongly affected by the selected threshold. The appropriate threshold for accurate diameter representation depends on the density of the bronchial wall. CONCLUSION: Our results suggest that in clinical practice a single threshold value cannot be used for imaging all segments of the tracheobronchial tree. While a value of -520 is appropriate for the trachea and lobar segments, values down to -720 could be needed on the level of segmental and subsegmental bronchi. At these levels, a threshold value about 65 HU more negative than the value where the artificial holes appear on the virtual bronchial walls could be used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P N Maniatis, C C Triantopoulou, I A Tsalafoutas, K S Malagari, I G Siafas, E A Psatha, E D Koulentianos, D A Kelekis. 2004. Threshold selection in virtual bronchoscopy: phantom study and clinical implications.. https://doi.org/10.1080/02841850410003761

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Bronchoscopist talks to you.

Fiberoptic bronchoscopy (FBS) is an important entry in the armamentarium of procedures listed in management of respiratory problems. It is a simple and a safe procedure. FBS has a great scope for diagnosis as well as therapy in pediatric respiratory illnesses. This article gives a practical overview of FBS in pediatric practice.

Bronchoscopes↗

Reprocessing endoscopes: United States perspective.

Endoscopes are used frequently for the diagnosis and therapy of medical disorders. For example, greater than 10000000 gastrointestinal endoscopic procedures are performed each year in the United States. Failure to employ appropriate cleaning and disinfection/sterilization of endoscopes has been responsible for multiple nosocomial outbreaks and serious, sometimes life-threatening, infections. Flexible endoscopes, by virtue of the site of use, have a high bioburden of microorganisms after use. The bioburden found on flexible gastrointestinal endoscopes following use has ranged from 10(5) to 10(10)CFU/ml, with the highest levels being found in the suction channels. Cleaning dramatically reduces the bioburden on endoscopes. Several investigators have shown a mean log(10) reduction factor of 4 (99.99%) in the microbial contaminants with cleaning alone. Cleaning should be done promptly following each use of an endoscope to prevent drying of secretions, allow removal of organic material, and decrease the number of microbial pathogens. Because the endoscope comes into intimate contact with mucous membranes, high-level disinfection is the reprocessing standard after each patient use. High-level disinfection refers to the use of a disinfectant (e.g., FDA-cleared chemical sterilant or high-level disinfectant) that inactivates all microorganisms (i.e., bacteria, viruses, fungi, mycobacteria) but not high levels of bacterial spores. The disinfection process requires immersion of the endoscope in the high-level disinfectant and ensuring all channels are perfused for the approved contact time (e.g., for ortho-phthaladehyde this is 12 min in the US). Following disinfection, the endoscope and channels are rinsed with sterile water, filtered water, or tapwater. The channels are then flushed with alcohol and dried using forced air. The endoscope should be stored in a manner that prevents recontamination. A protocol that describes the meticulous manual cleaning process, the appropriate training and evaluation of the reprocessing personnel, and a quality assurance program for endoscopes should be adopted and enforced by each unit performing endoscopic reprocessing.

Bronchoscopes↗

[Modern diagnostics of tracheal stenosis].

BACKGROUND: Numerous new modalities in computertomography (CT), in particular Multislice-Spiral-CT and Virtual Endoscopy, and novel developments in endoscopy and spirometry gave us reason to review the current state of the art in diagnostics of tracheal stenosis (TS). METHODS: This review evaluates the literature of the last decade regarding new trends and methods in diagnostics of tracheal stenosis. Pros and cons are discussed, and the future trends are highlighted. CONCLUSIONS: Spiral-CT scans at collimated slices of < or = 3 mm, PITCH < or = 1.5 and a segmentation level of - 350 HE permit a valid measurement of tracheal lumina. The flow-volume-plot is still the most important investigation to evaluate respiratory function in TS. Peak-Flow-Meters are suitable for patient self monitoring. The selective estimation of the TS related airway resistance using in situ measurements and numerical flow simulation studies are likely to reach importance in future. The ability to obtain exact measures from endoscopic recordings using EndoScan serves quality control in endoscopy. An objective comparison of different treatments becomes possible. Endosonography and methods for in-vitro tissue analysis (Optical Coherence Tomography) are more focused on the early diagnosis of malignant lesions. The Synopsis of endoscopy, CT-scan and spirometry provides the highest diagnostic accuracy today.

Bronchoscopes↗