Abstract

Bioanalysis frequently involves the measurement of very low analyte concentrations in complex and potentially variable matrices. It is not possible to test in validation every possible circumstance that may be encountered when analyzing study samples; logically, therefore, some risk of obtaining erroneous results exists when validated methods are applied to study samples. An initial attempt has been made to apply a risk management tool to the bioanalytical situation, with the hope that this will stimulate further discussion on the idea of more formally addressing "risk" with regards to bioanalytical method validation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C A James, M Breda, E Frigerio. 2004-06-29. Bioanalytical method validation: a risk-based approach?. https://doi.org/10.1016/j.jpba.2004.02.028

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Reactivation of Kaposi's sarcoma-associated herpesvirus by natural products from Kaposi's sarcoma endemic regions.

Kaposi's sarcoma (KS) and its causative agent, Kaposi's sarcoma associated herpesvirus (KSHV/HHV-8), a gamma2 herpesvirus, have distinctive geographical distributions that are largely unexplained. We propose the "oncoweed" hypothesis to explain these differences, namely that environmental cofactors present in KS endemic regions cause frequent reactivation of KSHV in infected subjects, leading to increased viral shedding and transmission leading to increased prevalence of KSHV infection as well as high viral load levels and antibody titers. Reactivation also plays a role in the pathogenesis of KSHV-associated malignancies. To test this hypothesis, we employed an in vitro KSHV reactivation assay that measured increases in KSHV viral load in KSHV infected primary effusion lymphoma (PEL) cells and screened aqueous natural product extracts from KS endemic regions. Of 4,842 extracts from 38 countries, 184 (5%) caused KSHV reactivation. Extracts that caused reactivation came from a wide variety of plant families, and extracts from Africa, where KSHV is highly prevalent, caused the greatest level of reactivation. Time course experiments were performed using 28 extracts that caused the highest levels of reactivation. The specificity of the effects on viral replication was examined using transcriptional profiling of all viral mRNAs. The array data indicated that the natural extracts caused an ordered cascade of lytic replication similar to that seen after induction with synthetic activators. These in vitro data provide support for the "oncoweed" hypothesis by demonstrating basic biological plausibility.

Biological Assay↗

Ring test assessment of the mKir2.1 growth based assay in Saccharomyces cerevisiae using parametric models and model-free fits.

Inward rectifying K+ (Kir) channels are a subfamily of the potassium channel superfamily. They mediate potassium influx into the cells, a process responding to the polarization state, a variety of intracellular messengers and specific auxiliary proteins, thereby they are involved in important physiological processes such as the pacemaker activity in the heart, insulin release, and potassium uptake in glial cells. The Saccharomyces cerevisiae mKir2.1 in vitro assay was subjected to a ring test assessment. Compound-associated mKir2.1 modulating effects were detected by growth determination of functionally complemented S. cerevisiae cells in a 96-well format within 15 h. Dose-response diagrams and EC50 value calculations were determined by parametric model and model-free fits using cubic spline interpolation. These characteristics were evaluated by statistical methods to determine reproducibility among working groups. Nonparametric bootstrap simulations of the variability of the data revealed that EC50 values of the mKir2.1 indicator strain were well-matched (81-92 microM), enabling unambiguous quantitative statements about inhibitory effects and no significant influence of the different laboratory conditions. Limitations of the assay include compounds/samples that are either insoluble under the conditions of the test or strongly cytotoxic to yeast. Thus, the described test is a sensitive and reliable tool that can be used in different laboratories and is applicable in drug discovery and development as simple and reliable prescreening procedure.

Biological Assay↗

An instrument for sorting of magnetic microparticles in a magnetic field gradient.

BACKGROUND: The goal of our bioassay technique is to demonstrate high throughput, highly parallel, and high sensitivity quantitative molecular analysis that will expand current biomedical research capabilities. To this end, we have built and characterized a magnetophoresis instrument using a flow chamber in a magnetic field gradient to sort magnetic microparticles by their magnetic moment for eventual use as biological labels. METHODS: The flow chamber consists of a sample inlet, differential sheath streams, and eight outlets for collecting the microparticles after they have traversed the chamber. Magnetic microparticles are injected into the flow chamber that is positioned in a linear magnetic field gradient. The trajectory for each microparticle is determined by its total magnetic moment and size. The resulting populations of monodispersed magnetic microparticles in the different outlet bins are sorted by their magnetic moment; with the highest magnetic moments being deflected the furthest. RESULTS: We have characterized the system for sorting both superparamagnetic and ferromagnetic microparticles with approximate diameters of 8 microm and 4.0-4.9 microm, respectively. To characterize the instrument, we used microparticles with a known size distribution and varied the transit time through the chamber. This is equivalent to varying the magnetic moment, while allowing us to hold the particle properties constant from run-to-run. We demonstrated the ability to reproducibly change the distribution of the particles in the collection bins by varying transit time in good agreement with theory. We identified hydrodynamic instabilities responsible for causing dispersion in the flow. Improvements to the flow chamber hydrodynamics such as reducing the aspect ratio between the sample inlet and the chamber depth and stabilizing the sheath flow resulted in narrow sorting distributions. We measured a sorting reproducibility (percentage of particles returning to their original bin upon resorting individual populations) of 84-89%. CONCLUSIONS: We have developed a simple magnetophoresis system for reproducibly sorting magnetic microparticles. This technique will permit the use of microparticles with a wide range of magnetic moments to create a wide range of magnetic labels. Careful consideration of system design and operational parameters enables reliable and reproducible sorting of microparticles with varying size and magnetic content.

Biological Assay↗