PubMed Health⌕ Search

PubMed · 15205129

Characterization and evolution of diffusion MR imaging abnormalities in stroke patients undergoing intra-arterial thrombolysis.

Abstract

BACKGROUND AND PURPOSE: Lesions revealed by pretreatment diffusion-weighted imaging (DWI) may not progress to infarction, and apparent diffusion coefficient (ADC) or DWI thresholds for tissue viability may exist. We evaluated the evolution of abnormal DWI findings in patients with acute stroke who underwent thrombolysis. METHODS: Sixteen patients with acute occlusion of the anterior circulation underwent DWI followed by intra-arterial thrombolysis; follow-up CT or MR imaging was performed after reperfusion therapy. Lesion volumes were measured on all images. In three patients with abnormal DWI findings that appeared normal at follow-up, ADC values, ADC ratios, and DWI ratios were obtained on a section-by-section basis in the DWI-hyperintense regions that were either abnormal or normal at follow-up. RESULTS: In three patients, part of the DWI-hyperintense tissue appeared normal and part appeared abnormal at follow-up imaging. In one of these patients, the lesion decreased by -35.6%. In the other two, lesion growth appeared in regions that appeared normal at initial DWI: in one, the overall change in size was -2.4%, and in the other, the lesion increased by 89.8%. Respective mean changes at follow-up in normal-appearing and abnormal-appearing regions were: ADC, 731.7 x 10(-6) mm(2)/s and 650.4 x 10(-6) mm (2)/s; ADC ratio, 0.92 and 0.78; and DWI ratio, 1.16 and 1.32 (P <.001 for all measures). CONCLUSION: In patients with acute stroke who undergo intra-arterial thrombolysis, most abnormal, pretreatment DWI findings indicate eventual infarction. In 19% of the patients described herein, DWI-hyperintense regions appeared normal at follow-up. ADC values, ADC ratios, and DWI ratios may be useful in identifying the portion of abnormal tissue that is potentially salvageable after reperfusion therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pamela W Schaefer, Alvand Hassankhani, Christopher Putman, A Gregory Sorensen, Lee Schwamm, Walter Koroshetz, R Gilberto Gonzalez. Characterization and evolution of diffusion MR imaging abnormalities in stroke patients undergoing intra-arterial thrombolysis.. https://pubmed.ncbi.nlm.nih.gov/15205129/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗