PubMed Health⌕ Search

PubMed · 15214537

A unifying framework for multi-criteria fluence map optimization models.

Abstract

Models for finding treatment plans for intensity modulated radiation therapy are usually based on a number of structure-based treatment plan evaluation criteria, which are often conflicting. Rather than formulating a model that a priori quantifies the trade-offs between these criteria, we consider a multi-criteria optimization approach that aims at finding the so-called undominated treatment plans. We present a unifying framework for studying multi-criteria optimization problems for treatment planning that establishes conditions under which treatment plan evaluation criteria can be transformed into convex criteria while preserving the set of undominated treatment plans. Such transformations are identified for many of the criteria that have been proposed to date, establishing equivalences between these criteria. In addition, it is shown that the use of a nonconvex criterion can often be avoided by transformation to an equivalent convex criterion. In particular, we show that models employing criteria such as tumour control probability, normal tissue complication probability, probability of uncomplicated tumour control, as well as sigmoidal transformations of (generalized) equivalent uniform dose are equivalent to models formulated in terms of separable voxel-based criteria that penalize dose in individual voxels.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Edwin Romeijn, James F Dempsey, Jonathan G Li. 2004-05-21. A unifying framework for multi-criteria fluence map optimization models.. https://doi.org/10.1088/0031-9155%2F49%2F10%2F011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of risk of deterministic effects in fluoroscopically guided procedures.

A methodology for the evaluation of skin dose distribution and possible skin injuries on patients undergoing interventional procedures has been developed as part of the European DIMOND programme. Relevant dosimetric data from the procedures are recorded and other specific measurements for skin dose evaluation (slow films for therapy, radiochromic films, thermoluminescence dosemeters and optically stimulated luminescence dosemeters) have been carried out. For non-cardiac and for some cardiac procedures, dose-area product values of 200 and 300 Gy cm2 were proposed, respectively, as a trigger level for further detailed skin dose investigation and possible clinical follow-up. Results from a survey of 191 selected complex procedures are reported. Out of all the patients included in the trial, 16% received skin doses > or =1.5 Gy. No skin injuries were found in any of the patients followed.

Dose-Response Relationship, Radiation↗

Dose response evaluation of a low-density normoxic polymer gel dosimeter using MRI.

A low-density (approximately 0.6 g cm(-3)) normoxic polymer gel, containing the antioxidant tetrakis (hydroxymethyl) phosponium (THP), has been investigated with respect to basic absorbed dose response characteristics. The low density was obtained by mixing the gel with expanded polystyrene spheres. The depth dose data for 6 and 18 MV photons were compared with Monte Carlo calculations. A large volume phantom was irradiated in order to study the 3D dose distribution from a 6 MV field. Evaluation of the gel was carried out using magnetic resonance imaging. An approximately linear response was obtained for 1/T2 versus dose in the dose range of 2 to 8 Gy. A small decrease in the dose response was observed for increasing concentrations of THP. A good agreement between measured and Monte Carlo calculated data was obtained, both for test tubes and the larger 3D phantom. It was shown that a normoxic polymer gel with a reduced density could be obtained by adding expanded polystyrene spheres. In order to get reliable results, it is very important to have a uniform distribution of the gel and expanded polystyrene spheres in the phantom volume.

Dose-Response Relationship, Radiation↗

Detection of radiation effects in polymer gel dosimeters using 129Xe NMR.

Polymer gel dosimeters consist of monomers, with or without cross-linking agents, dispersed in a gel. Upon exposure to ionizing radiation, polymerization proceeds within the gel matrix, thereby changing several measurable physical properties that can then be related quantitatively to absorbed dose. Several previous studies have examined how various nuclear magnetic resonance (NMR) properties, such as the relaxation rates of water protons, change with dose, and magnetic resonance imaging (MRI) has been used successfully to measure three-dimensional dose distributions in irradiated polymer gels. Here we report our first observations of the manner in which the chemical shift of xenon gas (129Xe) dissolved in a gel changes with absorbed dose, and we introduce the potential use of high resolution xenon NMR spectra for understanding better the dose response of gels. 129Xe possesses a large chemical shift range and xenon spectra are sensitive to subtle changes in the physical and chemical environments in which the gas is dissolved. For doses ranging from 0 Gy to 40 Gy we found that the mean chemical shift of 129Xe was linearly related to dose, and that the gel dosimeter could be described in terms of a two-component model undergoing fast exchange. We found no evidence of radiation damage to the gelatin matrix at doses between 0 Gy and 40 Gy. At 40 Gy, the fast-exchange model begins to break down, and distinct gelatin and poly(methacrylate) resonances are observed at higher doses. High resolution NMR measurements of xenon provide a novel method for probing radiation dose effects in irradiated polymer gels.

Dose-Response Relationship, Radiation↗