PubMed · 15261423
Environmental radon studies using solid state nuclear track detectors.
Abstract
The results of radon activity recorded in 70 dwellings of Nurpur area, Kangra district, Himachal Pradesh, India are reported. LR-115 Type 2 films in the bare mode were exposed for four seasons of three months each covering a period of one year for the measurement of indoor radon levels. The calibration constant of 0.020 tracks cm(-2) d(-1) per Bq m(-3) has been used to express radon activity in Bq m(-3). The annual average indoor radon concentrations in 17 different villages of the area are found to vary from 168+/-46 to 429+/-71. Most of the indoor radon values lie in the range of action levels (200-600 Bq m(-3)) recommended by International Commission on Radiological Protection.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Surinder Singh, Dinesh Kumar Sharma, Ajay Kumar. 2004. Environmental radon studies using solid state nuclear track detectors.. https://doi.org/10.1016/j.jenvrad.2004.01.029