PubMed Health⌕ Search

PubMed · 15271277

Classification algorithms for hip fracture prediction based on recursive partitioning methods.

Abstract

This article presents 2 modifications to the classification and regression tree. The authors improved the robustness of a split in the test sample approach and developed a cost-saving classification algorithm by selecting noninferior to the optimum splits from variables with lower cost or being used in parent splits. The new algorithm was illustrated by 43 predictive variables for 5-year hip fracture previously documented in the Study of Osteoporotic Fractures. The authors generated the robust optimum classification rule without consideration of classification variable costs and then generated an alternative cost-saving rule with equivalent diagnostic utility. A 6-fold cross-validation study proved that the cost-saving alternative classification is statistically noninferior to the optimal one. Their modified classification and regression tree algorithm can be useful in clinical applications. A dual X-ray absorptiometry hip scan and information from clinical examinations can identify subjects with elevated 5-year hip fracture risk without loss of efficiency to more costly and complicated algorithms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hua Jin, Ying Lu, Steven T Harris, Dennis M Black, Katie Stone, Marc C Hochberg, Harry K Genant. Classification algorithms for hip fracture prediction based on recursive partitioning methods.. https://doi.org/10.1177/0272989x04267009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A 3D analysis of mechanically stressed dentin-adhesive-composite interfaces using X-ray micro-CT.

Dentin bonding systems (DBS) have been developed in order to bond restorative materials (i.e. composite) to tooth tissues when function and integrity have to be re-established. Adhesion to dentin results from the penetration of DBS into the demineralised substrate constituted by a conditioned collagen network. The long-term stability of a restored tooth is mainly affected by the seal of the restorative material on the dental structures. Although leakage through the dentin-DBS interface has been widely reported, 3D investigation technique and accurate non-destructive measurements of leakage as functions of mechanical cycling have never been provided. To address these issues, the properties of the material interface are analysed using micro-tensile static and dynamic tests, assisted by the finite element modelling and by the X-ray computed micro-tomography. The dual energy absorption technique, with the synchrotron beam light, has been developed to investigate, in a non-destructive manner, the effect of mechanical cycling on leakage of a silver nitrate staining solution at the dentin-DBS interface. The effect of the pulpal roof on the stress distribution in the coronal dentin-DBS-composite interface has been investigated and the level at which the state of stress can be assumed to be uniform within acceptable limits has been defined. The tensile static and dynamic results suggest that the adhesive strength for the multi-step DBS resulted significantly higher than the other investigated DBS. Imaging results indicate that 3D leakage occurs radially at the dentin-adhesive interface through the interface itself rather than through the unconditioned dentin bulk; moreover, the dynamic tensile loading allows a more diffuse staining penetration.

Absorptiometry, Photon↗

Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine arthroplasty model. Part II: in vivo investigation.

The polyurethane (PU) elastomer Corethane 80A (Corvita) is being considered as the acetabular bearing material in a novel total replacement hip joint. Its biostability was investigated in vitro (Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine arthroplasty model. Part I: material selection and evaluation, Biomaterials, in press) together with three other commercially available biomedical PUs: Pellethane 2363-80A (DOW Chemical), a polyhexamethylene oxide based PU, PHMO-PU (CSIRO, not supplied as a commercial product) and ChronoFlex AL-80A (CardioTech). From the in vitro studies, Corethane 80A displayed the best overall resistance to hydrolysis, ESC, MIO and calcification, followed by ChronoFlex 80A and PHMO-PU, with Pellethane 80A being the least stable. Building on the in vitro investigation, the follow-up in vivo study (reported here) assessed Corethane 80A as the bearing layer in a prototype compliant layer acetabular cup, in a fully functioning ovine total hip arthoplasty (THA) model. PU degradation in the retrieved cups was analysed using a range of analytical and physical-testing methods including mechanical testing, differential scanning calorimetry, Fourier transform infrared spectroscopy and environmental scanning electron microscopy. The Corethane 80A functioned well in the THA model, with the bearing surfaces of the retrieved hip cups showing no significant evidence of biodegradation or wear damage after 3 years in vivo. The findings in this study provide compelling evidence for the biostability and effectiveness of acetabular cups incorporating a Corethane 80A compliant bearing layer.

Absorptiometry, Photon↗

Relation of BMI to fat and fat-free mass among children and adolescents.

OBJECTIVE: Although the body mass index (BMI, kg/m2) is widely used as a surrogate measure of adiposity, it is a measure of excess weight, rather than excess body fat, relative to height. We examined the relation of BMI to levels of fat mass and fat-free mass among healthy 5- to 18-y-olds. METHODS AND PROCEDURES: Dual-energy X-ray absorptiometry was used to measure fat and fat-free mass among 1196 subjects. These measures were standardized for height by calculating the fat mass index (FMI, fat mass/ht2) and the fat-free mass index (FFMI, fat-free mass/ht2). RESULTS: The variability in FFMI was about 50% of that in FMI, and the accuracy of BMI as a measure of adiposity varied greatly according to the degree of fatness. Among children with a BMI-for-age > or =85th P, BMI levels were strongly associated with FMI (r=0.85-0.96 across sex-age categories). In contrast, among children with a BMI-for-age <50th P, levels of BMI were more strongly associated with FFMI (r=0.56-0.83) than with FMI (r=0.22-0.65). The relation of BMI to fat mass was markedly nonlinear, and substantial differences in fat mass were seen only at BMI levels > or =85th P. DISCUSSION: BMI levels among children should be interpreted with caution. Although a high BMI-for-age is a good indicator of excess fat mass, BMI differences among thinner children can be largely due to fat-free mass.

Absorptiometry, Photon↗