PubMed Health⌕ Search

PubMed · 15291028

Single-unit artificial intervertebral disc.

Abstract

OBJECT: The authors describe a new type of artificial disc called a single-unit artificial disc (SUAD). It is a single-unit disc without components, and there is no fixation system with which to maintain it in the disc space. It is theorized that its shape, hardness, and surface consistency, together with the compressive force exerted by the body's axial load, should be adequate to maintain the position of the disc in the disc space. In this paper the authors present their results of the kinematic tests in which the stability and integrity of the SUADs was tested. METHODS: Panorobot was used for kinematic test fixture for fatigue testing for different types of SUAD. The test was performed after placing the disc between the C-5 and C-6 vertebral bodies (VBs) obtained from a cadaver. Eight pounds of weight was placed on the top of the container housing the C-5 VB to account for the weight of the head. The robot performed the following movements: 1) flexion-extension, 4.7 degrees each; 2) lateral left-right bending, +/- 2.1 degrees; and 3) coupled rotation, +/- 3.8 degrees. Two flat discs (FDs) of 85 durometer (D), four 30D FD, two recess-edged discs (REDs) of 85D, and four custom-designed discs (CDDs) (custom molded to the disc space) of 30D were tested. None of the discs showed cracks or breakage at the end of the study. After 1 million cycles of excursions all 85D and 30D FD, and both 85D REDs showed weight loss. The 30D CDDs showed minimal weight gain at 1 million cycles. One of the CDDs, tested up to 5 million cycles, did lose weight at 5 million cycles. One 85D FD was extruded after 0.2 million cycles and one 85D RED rotated within the disc space. All other discs maintained their position in the disc space. Dimensional changes were minimal. Scanning electron microscopy of particles collected from one 30D CDD sample after 1 million cycles showed rough irregular granular particles 1 to 600 microm in diameter. CONCLUSIONS: These findings show that a 30D SUAD can maintain its position in the disc space without any anchoring device. Furthermore, at 1 million cycles of testing of 30 D SUAD, FDs did as well as the CDDs. This may be because softer discs mold to changes in dimension of the disc space. In addition the softer discs tend to wear less than the harder ones. Further fatigue study of 10 million cycles is needed to determine long-term efficacy, and the effects of wear on particles surrounding the joints need to be studied.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Russell Alberts, Arun-Angelo Patil, Dongxue Zhou. 2004. Single-unit artificial intervertebral disc.. https://doi.org/10.3171/spi.2004.1.1.0095

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Artificial muscles based on liquid crystal elastomers.

This paper presents our results on liquid crystal (LC) elastomers as artificial muscle, based on the ideas proposed by de Gennes. In the theoretical model, the material consists of a repeated series of main-chain nematic LC polymer blocks, N, and conventional rubber blocks, R, based on the lamellar phase of a triblock copolymer RNR. The motor for the contraction is the reversible macromolecular shape change of the chain, from stretched to spherical, that occurs at the nematic-to-isotropic phase transition in the main-chain nematic LC polymers. We first developed a new kind of muscle-like material based on a network of side-on nematic LC homopolymers. Side-on LC polymers were used instead of main-chain LC polymers for synthetic reasons. The first example of these materials was thermo-responsive, with a typical contraction of around 35-45% and a generated force of around 210 kPa. Subsequently, a photo-responsive material was developed, with a fast photochemically induced contraction of around 20%, triggered by UV light. We then succeeded in preparing a thermo-responsive artificial muscle, RNR, with lamellar structure, using a side-on nematic LC polymer as N block.Micrometre-sized artificial muscles were also prepared. This paper illustrates the bottom-up design of stimuli-responsive materials, in which the overall material response reflects the individual macromolecular response, using LC polymer as building block.

Artificial Organs↗

A design framework to model retinas.

Neuro-engineering is providing biomedical engineers with technology to interface the nervous system, which is useful to create prosthetic devices to palliate sensorial or motor disabilities. Motivated by the success of cochlear implants for deaf patients, we are now facing the challenge of creating a prosthetic visual system for the blind. An artificial retina whose response to stimuli can be matched to biological ones is required. To make easier the task of modeling, tuning and testing these retinal models, we have created a software tool that allows flexible and parametric definition and testing of retina-like models. The program can be fed with a variety of video or image sources, and the results can be easily compared to biological recordings of retinal ganglionar activity in response to the same stimuli. This tool can be useful, not only for this prosthetic purpose, but for any other research involving bio-inspired image processing with a neuromorphic output.

Artificial Organs↗