AAPM tutorial. CT image detail and noise.

Abstract

Two important characteristics of the computed tomographic (CT) image that affect the ability to visualize anatomic structures and pathologic features are blur and noise. Increased blurring reduces the visibility of small objects (image detail); increased visual noise reduces the visibility of low-contrast objects. Sources of blurring in CT include the size of the sampling aperture (which can be regulated by the focal spot size and the detector size), the size of the voxels, and the reconstruction filter selected. Noise is caused by the variation in attenuation coefficients between voxels. Use of small voxels and edge-enhancing filters helps reduce blurring and improve visibility of fine details. However, small voxels absorb fewer photons and therefore result in increased noise. Noise can be reduced by using large voxels, increasing radiation dose, or using a smoothing filter, but this filter increases blurring. An optimized protocol for a specific clinical study must take these physical principles into account and be adjusted to give proper balance among detail, low noise, and patient exposure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Sprawls. 1992. AAPM tutorial. CT image detail and noise.. https://doi.org/10.1148/radiographics.12.5.1529128

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance comparison of an active matrix flat panel imager, computed radiography system, and a screen-film system at four standard radiation qualities.

Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.

Radiographic Image Enhancement↗