PubMed Health⌕ Search

PubMed · 15294310

Processing X-ray images to eliminate irrelevant structures that mask important features.

Abstract

In a plane radiographic image, there generally is an important area of interest (AOI). Too often, the AOI is partially masked by images of other overlapping and underlying structures that may be in front of or behind the AOI. An important adjunct to radiological diagnosis would be the capability of eliminating images of such masking structures to isolate the AOI for more detailed examination. We described a computerized method that utilizes a stereo pair of plane X-ray images to enable radiologists to interact with these images for first identifying for the computer the AOI and then directing the computer to eliminate all structures in front of and behind the AOI. The result is a plane X-ray image or a stereo X-ray image pair that includes only the AOI, but not any overlapping or underlying structures. The method uses a stereo pair of X-rays and the 3D perception of radiologists. 3D perception involves eye convergence and lens focus as well as cues, such as parallax and relative sizes. Convergence of the eyes is by far the strongest factor in 3D visualization. The horizontal separation or disparity between points in the left and right eye images on a screen or X-ray film produces convergence which determines an object's perceived depth in visual 3D space. All points in a given perceived depth plane have the same disparity on the screen. In theory, a given depth plane can be eliminated from the 3D image by shifting one image and then the other image of a stereo pair horizontally by the distance of the disparity of the depth plane, and subtracting. A new stereo image pair is thereby produced in which points only of the depth plane do not appear. However, in practical situations, certain artifacts arise that must be considered. The method has the potential for important applications in many areas of medical imaging processing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zegang Dong, Robert S Ledley. 2004. Processing X-ray images to eliminate irrelevant structures that mask important features.. https://doi.org/10.1016/j.compmedimag.2004.06.001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transhepatic vascular access for diagnostic and interventional procedures: techniques, outcome, and complications.

Early or multiple cardiac catheterizations may result in occlusion of the femoral veins prohibiting their use. The internal jugular or sub-clavian approach may be an appropriate alternative. However, these approaches may not be suitable in patients with surgical interruption of the superior vena cava. In other patients, they may not allow easy access to certain areas of the heart. The transhepatic approach is an important alternative route for performing cardiac catheterization and interventions. Depending on the planned procedure, it may be the preferred route to perform the cardiac catheterization even in the presence of patent femoral veins. The indications, technical details and potential complications of this approach are discussed.

Angiography↗

Embolization for a bleeding pelvic fracture in a patient with persistent sciatic artery.

Emergency embolization for a bleeding pelvic fracture was performed in a patient with persistent sciatic artery, a rare anatomic variation in which the internal iliac artery continues to the popliteal artery. Successful hemostasis was achieved without complications by means of selective catheterization into each branch of the internal iliac artery. Awareness of this unusual vascular anatomy is critically important to avoid serious complication of emergency embolization.

Angiography↗