PubMed Health⌕ Search

PubMed · 15294402

Differing operational outcomes with six commercially available automated external defibrillators.

Abstract

INTRODUCTION: In general automated external defibrillators (AED) are handled easily, but some untrained lay rescuers may have major problems with the use of such products. This may result in delayed shock delivery and delay in basic life support (BLS) after use of the AED. To study the effect of voice prompts and design solutions we tested the time from the first shock to the initiation of BLS for six defibrillators available in Austria. METHODS: Volunteers, who had no AED training, were evaluated to see when they delivered the first shock and how often BLS was started after the voice prompts were given by the defibrillators. RESULTS: Time to first shock delivered ranged from 78 (95% CI: 68-89) to 128 (95% CI: 110-146)s. The defibrillator-type had a significant influence on the time to first shock delivered (P < 0.0001). The proportion of volunteers who started BLS after defibrillation ranged from 93 to 33% and differed significantly between the AEDs used (P < 0.03). CONCLUSIONS: We demonstrated that there are significant differences between AEDs, concerning important operational outcomes like time to first shock and the start of BLS. Further research and development is urgently required to optimise user-friendliness and operational outcomes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roman Fleischhackl, Heidrun Losert, Moritz Haugk, Philip Eisenburger, Fritz Sterz, Anton N Laggner, Harald Herkner. 2004. Differing operational outcomes with six commercially available automated external defibrillators.. https://doi.org/10.1016/j.resuscitation.2004.03.018

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of ventilation and chest compression performance by bystanders using the Impact Model 730 ventilator and a conventional bag valve with mask in a model of adult cardiopulmonary arrest.

"Bystanders" or lay persons are typically the first caregivers to attend to a victim of out-of-hospital cardiopulmonary arrest. Astronaut crew medical officers (CMO) play a similar role to bystanders aboard the International Space Station (ISS). Studies have demonstrated the importance of bystander cardiopulmonary resuscitation (BCPR) for patient survival before the arrival of emergency medical care. Recent apprehension from bystanders about the threat of contracting communicable diseases during BCPR, however, has led to the consideration of other ventilation systems such as the bag-valve mask (BVM) and automatic transport ventilators (ATV). BVM use is called for during CPR aboard the ISS. This study evaluated the ventilation and compression performance of 40 basic CPR-trained bystanders using either a BVM (adult-sized self-inflating bag with face mask) or an ATV (Model 730 ventilator (M730), Impact Instrumentation, Inc., West Caldwell, NJ). Each two-bystander team gave BCPR to a simulated cardiopulmonary arrest victim using the 2-breath/15-compression cycle for 4 min and then switched roles for another 4-min interval. Compared to BVM use, the M730 led to significantly (p<0.05) lower number of breaths, smaller tidal volumes, airway flows, airway pressures, volume of gas entering the stomach per breath and chest compressions for the 4-min period. The M730 also enabled a bystander to meet the recommendation of 4-breath and compression cycles per minute as per Guidelines 2000. Lastly, ease-of-use scores were significantly higher for the M730 compared to the BVM. Overall, the data suggest that the M730 improves the quality of performance for a bystander performing BCPR.

Cardiopulmonary Resuscitation↗