PubMed Health⌕ Search

PubMed · 15301964

A software utility for creating interactive maps for 2D gel-based proteomics.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Junyu Li, Sheng Liu, Travis Osterman, Yinong Zhang, Heather Coppage, Nathan Pedrick, Frank A Witzmann. 2004-09-01. A software utility for creating interactive maps for 2D gel-based proteomics.. https://doi.org/10.1016/j.ab.2004.03.058

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transpalpebral tonometry with a digital tonometer in healthy eyes and after penetrating keratoplasty].

PURPOSE: The Goldmann applanation technique established itself as gold standard for clinical intraocular pressure (IOP) measurement. But the device measures by corneal touch and presupposes corneal conditions within a normal range. So precise determination of IOP is crucial in corneal disorders and after corneal surgery. This pilot study presents tonometry data of normal and postkeratoplasty eyes measured transpalpebrally with a digital tonometer in comparison to Goldmann tonometry. METHOD: The TGDc-01 tonometer is based on a ballistic principle of measurement. IOP was measured in 50 healthy eyes (group 1) and 40 eyes after penetrating keratoplasty (group 2) first by the TGDc-01 and after 3 minutes by Goldmann tonometry (Haag-Streit). Subjective refraction, keratometry and ultrasonic pachymetry were performed in all eyes. The IOP measurements in the postkeratoplasty eyes were done when corneal epithelium was fully closed and only a medium suture edema could be observed. RESULTS: The Pearson's product-moment correlation was r=0,46 for group 1 and 0,65 for group 2. Using the concordance correlation coefficient the value showed a reproducibility index of r(c)=0,44 in group 1 and r(c)=0,60 in group 2. Following the Bland-Altman-analysis 58% of the cases in group 1 had a difference between the two instruments of maximum 3 mmHg. In group 2, 53,5% of the eyes showed an absolute difference between Goldmann and TDGc-01 of 3 mmHg or less. CONCLUSION: A transpalpebral measurement technique-avoiding corneal contact-seems to be an alternative choice in patients with corneal pathologies and after corneal surgery. The TGDc-01 tonometer provided mostly similar results compared to the Goldmann device, but with fluctuations. Keeping the deviations between the two methods in mind we recommend, however, the use of the transpalpebral approach only in combination with other techniques (palpation, indentation) to obtain enough reliability of IOP information in problem eyes.

Data Interpretation, Statistical↗

Modeling of dispersed-drug release from two-dimensional matrix tablets.

A mathematical model was developed and analytical solutions were obtained for dispersed-drug release from two-dimensional matrix tablets in a perfect sink. This model can be used to describe kinetics of solute release from matrices with isotropic or anisotropic properties. Moving boundaries of dispersed-drug in both radial and axial directions and release kinetics were predicted by the model. Various factors influencing release kinetics were analyzed including the ratio of initial solute loading (C0) to solute solubility (Cs), the anisotropy of the matrix and the aspect ratio of tablet radius to the half-thickness. The model is also applicable to 1-D planar or 1-D cylindrical geometries when R/H is larger than 100 or smaller than 0.01.

Data Interpretation, Statistical↗