Quantifying labial blood flow using optical Doppler tomography.

Abstract

OBJECTIVES: Changes in the oral microvasculature occur in a variety of diseases. Optical Doppler tomography (ODT) combines laser Doppler flowmetry with optical coherence tomography (OCT) to produce high-resolution tomographic images of biological tissues that also detect the velocity and direction of blood flow. The objective of this study was to determine the feasibility of ODT to image labial blood flow. A prototype ODT imaging system was constructed that characterized and measured labial blood flow in healthy subjects. MATERIALS AND METHODS: A prototype ODT instrument was constructed using a diode light source with a central wavelength of 1300 nanometers, a 40-nanometer spectral width and 2.4 microwatts output power. To verify the accuracy of the system, the flow rates of a phantom material (Intralipid) pumped through a capillary tube at various speeds was measured. To evaluate the clinical feasibility of the ODT prototye, the mucosal aspect of the upper and lower lips at the midline was imaged in 9 healthy volunteers. The sample arm of the instrument consisted of a fiberoptic probe with a 2-mm in diameter polished glass lens attached to the end. The probe was placed approximately 3 mm from the mucosal surface of the lip and oriented perpendicular to the surface. A motorized translation stage moved the fiber in a superior to inferior direction while the subject's head was stabilized by placing the chin into a chin rest. Imaging time for a 12-mm x 2.5-mm scan was approximately 64 seconds. RESULTS: The phantom experiments revealed that accuracy of this novel ODT prototype to measure flow was within 5%. In vivo labial blood flow velocity ranged from 11.8 to 43.1 mm/second in the upper lip and 8.2 to 53.2 mm/second in the lower lip. There were no statistically significant differences between flow rates in the upper and lower lips. OCT images and Doppler velocity signals were successfully integrated producing in vivo images of labial blood in all of the subjects (15 images). The resulting cross-sectional images revealed microscopic details of labial structures and, to the best of our knowledge, are the first ODT images of the labial microvasculature. CONCLUSIONS: The results of this in vivo study prove the feasibility of ODT to quantify labial blood flow and produce high spatial resolution images specifically localizing vessels anatomically. ODT provides both flow speed and flow direction information. ODT is noninvasive and offers the advantages of high volumetric flow sensitivity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Linda L Otis, Daquing Piao, Carolyn W Gibson, Quing Zhu. 2004. Quantifying labial blood flow using optical Doppler tomography.. https://doi.org/10.1016/j.tripleo.2004.03.030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasonographic, computed tomographic and magnetic resonance imaging anatomy of the normal canine stifle joint.

Ultrasonographic (US), magnetic resonance (MR) and computed tomographic (CT) images of normal canine stifle joints were obtained and compared with plastinated cross-sectional slices of cadaver specimens from the same dogs. The bony and articular structures were identified and correlated with the three diagnostic imaging modalities. These results provide an atlas of normal cross-sectional US, MR and CT anatomy of the canine stifle, which can be used for the interpretation of stifle images from any of these imaging modalities.

Anatomy, Cross-Sectional↗

Design and characterization of a digital image acquisition system for whole-specimen breast histopathology.

We have developed a digital histopathology imaging system capable of producing a three-dimensional (3D) representation of histopathology from an entire lumpectomy specimen. The system has the potential to improve the accuracy of surgical margin assessment in the treatment of breast cancer by providing finer sampling and 3D visualization. A scanning light microscope was modified to allow digital photomicrography of a stack of large (up to 120x170 mm2) histology slides cut serially through the entire specimen. The images are registered and displayed in 2D and 3D. The design of the system, which reduces or eliminates the appearance of 'tiling' and 'seam' artefacts inherent in the scanning method, is described and its resolution, contrast/noise and coverage properties are characterized through measurements of the modulation transfer function (MTF), depth of field (DOF) and signal difference to noise ratio (SDNR). The imaging task requires a lateral resolution of 5 microm, an SDNR of 5 between relevant features, 'tiling artefact' at a level below the detectability threshold of the eye, and 'seam artefact' of less than 5-10 microm. The tests demonstrate that the system is largely adequate for the imaging task, although further optimizations are required to reduce the degradation of coverage incurred by seam artefact.

Anatomy, Cross-Sectional↗

Mechanical effects of genioglossus muscle stimulation on the pharyngeal airway by MRI in cats.

To examine the regional mechanical effects of selective genioglossus muscle activation on pharyngeal airway size and function, magnetic resonance images of the pharyngeal airway were obtained in five paralyzed, anesthetized cats over a range of positive and negative pressures in an isolated, sealed upper airway. When all results across pressure levels and pharyngeal regions were analyzed, genioglossus stimulation significantly increased the cross-sectional area (CSA) of the nasopharyngeal airway. Within specific regions, stimulation tended toward significantly increasing cross-sectional airway area in the mid-nasopharynx. Despite its dilating effect, genioglossus muscle stimulation did not alter compliance in the nasopharyngeal airway, as evidenced by the similar slopes of the pressure versus cross-sectional area relationships with and without stimulation. Finally, airway shape in the mid pharynx became more circular with either increased airway pressure or genioglossus stimulation. The results indicate that selective stimulation of the genioglossus muscle dilates the nasopharynx and provide evidence that stimulation of the genioglossus alone does not alter airway compliance.

Anatomy, Cross-Sectional↗