PubMed Health⌕ Search

PubMed · 15317067

Beyond weight control.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Janine Freeman. 2003. Beyond weight control.. https://pubmed.ncbi.nlm.nih.gov/15317067/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of a new blood glucose monitoring system with auto-calibration for home and hospital bedside use.

A new self-calibrating blood glucose monitoring system (BGMS) was evaluated in a series of clinical studies with both ambulatory subjects and with hospitalized patients. The new BGMS requires a 0.6microL sample volume, provides results in 15s, and uses a glucose dehydrogenase chemistry that is oxygen independent. In the first study, Ascensia Contour meters calibrated to whole blood were tested by health care professionals (HCP) and lay users at two clinical sites. Both HCPs and lay users obtained results that fulfilled the ISO 15197:2003 criteria that 95% of self-monitoring blood glucose (SMBG) measurements should fall within +/-20% (for blood glucose (BG) concentrations> or =4.2mmol/L or +/-0.83mmol/L for BG concentrations<4.2mmol/L) of the laboratory value. Lay users and HCPs obtained 97.2 and 96.7% of glucose results within ISO criteria, respectively. In a second study, HCPs assayed blood samples from patients at the hospital bedside using meters calibrated to give whole blood glucose and meters calibrated to give plasma glucose results. Overall, 94.7% of the measurements met the ISO 15197:2003 criteria. Most lay subjects rated the BGMS as either excellent or very good in a questionnaire, and were able to use it properly without training. These findings indicate that this new BGMS is a convenient and accurate instrument system suitable for both hospital bedside use by HCPs and for SMBG by people who routinely monitor their blood glucose.

Blood Glucose↗

Determination of confidence intervals of metabolic fluxes estimated from stable isotope measurements.

Metabolic fluxes, estimated from stable isotope studies, provide a key to quantifying physiology in fields ranging from metabolic engineering to the analysis of human metabolic diseases. A serious drawback of the flux estimation method in current use is that it does not produce confidence limits for the estimated fluxes. Without this information it is difficult to interpret flux results and expand the physiological significance of flux studies. To address this shortcoming we derived analytical expressions of flux sensitivities with respect to isotope measurements and measurement errors. These tools allow the determination of local statistical properties of fluxes and relative importance of measurements. Furthermore, we developed an efficient algorithm to determine accurate flux confidence intervals and demonstrated that confidence intervals obtained with this method closely approximate true flux uncertainty. In contrast, confidence intervals approximated from local estimates of standard deviations are inappropriate due to inherent system nonlinearities. We applied these methods to analyze the statistical significance and confidence of estimated gluconeogenesis fluxes from human studies with [U-13C]glucose as tracer and found true limits for flux estimation in specific human isotopic protocols.

Blood Glucose↗