PubMed Health⌕ Search

PubMed · 15325352

Combining voxel intensity and cluster extent with permutation test framework.

Abstract

In a massively univariate analysis of brain image data, statistical inference is typically based on intensity or spatial extent of signals. Voxel intensity-based tests provide great sensitivity for high intensity signals, whereas cluster extent-based tests are sensitive to spatially extended signals. To benefit from the strength of both, the intensity and extent information needs to be combined. Various ways of combining voxel intensity and cluster extent are possible, and a few such combining methods have been proposed. Poline et al.'s [NeuroImage 16 (1997) 83] minimum P value approach is sensitive to signals whose either intensity or extent is significant. Bullmore et al.'s [IEEE Trans. Med. Imag. 18 (1999) 32] cluster mass method can detect signals whose intensity and extent are sufficiently large, even when they are not significant by intensity or extent alone. In this work, we study such combined inference methods using combining functions (Pesarin, F., 2001. Multivariate Permutation Tests. Wiley, New York) and permutation framework [Holmes et al., J. Cereb. Blood Flow Metab. 16 (1996) 7], which allow us to examine different ways of combining voxel intensity and cluster extent information without knowing their distribution. We also attempt to calibrate combined inference by using weighted combining functions, which adjust the test according to signals of interest. Furthermore, we propose meta-combining, a combining function of combining functions, which integrates strengths of multiple combining functions into a single statistic. We found that combined tests are able to detect signals that are not detected by voxel or cluster size test alone. We also found that the weighted combining functions can calibrate the combined test according to the signals of interest, emphasizing either intensity or extent as appropriate. Though not necessarily more sensitive than individual combining functions, the meta-combining function is sensitive to all types of signals and thus can be used as a single test summarizing all the combining functions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Satoru Hayasaka, Thomas E Nichols. 2004. Combining voxel intensity and cluster extent with permutation test framework.. https://doi.org/10.1016/j.neuroimage.2004.04.035

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗