Fast and robust parameter estimation for statistical partial volume models in brain MRI.

Abstract

Due to the finite spatial resolution of imaging devices, a single voxel in a medical image may be composed of mixture of tissue types, an effect known as partial volume effect (PVE). Partial volume estimation, that is, the estimation of the amount of each tissue type within each voxel, has received considerable interest in recent years. Much of this work has been focused on the mixel model, a statistical model of PVE. We propose a novel trimmed minimum covariance determinant (TMCD) method for the estimation of the parameters of the mixel PVE model. In this method, each voxel is first labeled according to the most dominant tissue type. Voxels that are prone to PVE are removed from this labeled set, following which robust location estimators with high breakdown points are used to estimate the mean and the covariance of each tissue class. Comparisons between different methods for parameter estimation based on classified images as well as expectation--maximization-like (EM-like) procedure for simultaneous parameter and partial volume estimation are reported. The robust estimators based on a pruned classification as presented here are shown to perform well even if the initial classification is of poor quality. The results obtained are comparable to those obtained using the EM-like procedure, but require considerably less computation time. Segmentation results of real data based on partial volume estimation are also reported. In addition to considering the parameter estimation problem, we discuss differences between different approximations to the complete mixel model. In summary, the proposed TMCD method allows for the accurate, robust, and efficient estimation of partial volume model parameters, which is crucial to a variety of brain MRI data analysis procedures such as the accurate estimation of tissue volumes and the accurate delineation of the cortical surface.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jussi Tohka, Alex Zijdenbos, Alan Evans. 2004. Fast and robust parameter estimation for statistical partial volume models in brain MRI.. https://doi.org/10.1016/j.neuroimage.2004.05.007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impact of the z-flying focal spot on resolution and artifact behavior for a 64-slice spiral CT scanner.

The effect of the z-flying focal spot (zFFS) technology was evaluated by simulations and measurements with respect to resolution and artifact behavior for a 64-slice spiral cone-beam computed tomography (CT) scanner. The zFFS alternates between two z-positions of the X-ray focal spot, acquiring two slices per detector row, which results in double sampling in the z-direction. We implemented a modified reconstruction that is able to obtain images as they would be without zFFS. A delta phantom equipped with a thin gold disc was used to measure slice sensitivity profiles (SSP), and a high-contrast bar phantom was used to quantify the resolution in the x/z-plane with and without zFFS. The zFFS decreases the full width at half maximum (FWHM) of the SSPs by a factor of about 1.4. The double z-sampling allows the separation of 0.4 mm bars in the z-direction compared with 0.6 mm in the case without zFFS. The zFFS effectively reduces windmill artifacts in the reconstructed images while maintaining the transverse resolution, even at the largest available pitch value of 1.5.

Artifacts↗

Apparatus for rapid adjustment of the degree of alignment of NMR samples in aqueous media: verification with residual quadrupolar splittings in (23)Na and (133)Cs spectra.

NMR spectra of (23)Na(+) and (133)Cs(+) in gelatine in a silicone rubber tube that was stretched to various extents showed remarkably reproducible resonance multiplicity. The relative intensities of the components of the split peaks had ratios, 3:4:3, and 7:12:15:16:15:12:7, respectively, that conformed with those predicted using a Mathematica program. The silicone-rubber tube was sealed at its lower end by a small rubber stopper and placed inside a thick-walled glass tube. Gelatine was injected in solution into the silicone tube and 'set' by cooling below 30 degrees C. A plastic thumb-screw held the silicone tube at various degrees of extension, up to approximately 2-fold. After constituting the gel in buffers containing NaCl and CsCl, both (23)Na and (133)Cs NMR spectroscopy revealed that after stretching the initial single Lorentzian line was split into a well-resolved triplet and a heptet, respectively. This was interpreted as being due to coupling between the electric quadrupoles of the nuclei and the average electric field gradient tensor of the collagen molecules of gelatine; these molecules became progressively more aligned in the direction of the main magnetic field, B(0), of the vertical bore magnet, as the gel was stretched. This apparatus provides a simple way of demonstrating fundamental physical characteristics of quadrupolar cations, some characteristics of gelatine under stretching, and a way to invoke static distortion of red blood cells. It should be useful with these and other cell types, for studies of metabolic and membrane transport characteristics that may change when the cells are distorted, and possibly for structural studies of macromolecules.

Artifacts↗