PubMed Health⌕ Search

PubMed · 15327023

Analytical quality specifications for common reference intervals.

Abstract

Interpretation of laboratory test results requires comparison to some type of reference value or reference interval. These comparisons can be cross-sectional (population-based reference interval and cut-off values) or longitudinal (reference change value). Quality specifications for cross-sectional comparison have been established by determining the influence of analytical bias and imprecision on the percentage of the healthy population falling outside the reference limits, when sharing population-based reference intervals in a Gaussian distribution of results. Quality specifications for longitudinal comparisons are equally important and are often overlooked, since less work has been done in this area. Some criteria suggest that a difference between consecutive results designates a true change in a patient health status when the difference is higher than the within-subject biological variation plus the within-laboratory analytical variation. In this chapter we discuss the clinical considerations and laboratory-related factors that must be considered when quality specifications are applied to sharing reference comparisons. Real life experience shows that different analytical methods can produce comparable results when common quality goals are established, and quality can be achieved through a willingness to work together. Within the existing organization, the current specifications for analytical quality and a dedication to quality health care makes it possible to achieve transferability between laboratories within a geographic area.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Carmen Ricós, Maria Vicenta Doménech, Carmen Perich. 2004. Analytical quality specifications for common reference intervals.. https://doi.org/10.1515/cclm.2004.140

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lab-on-a-chip devices for global health: past studies and future opportunities.

A rapidly emerging field in lab-on-a-chip (LOC) research is the development of devices to improve the health of people in developing countries. In this review, we identify diseases that are most in need of new health technologies, discuss special design criteria for LOC devices to be deployed in a variety of resource-poor settings, and review past research into LOC devices for global health. We focus mainly on diagnostics, the nearest-term application in this field.

Clinical Chemistry Tests↗

A note on the use of outlier criteria in Ontario laboratory quality control schemes.

OBJECTIVES: This paper examines the pitfalls that arise when an outlier is assessed using a criterion based on a fixed multiple of the standard deviation rather than an established statistical test. Although the former approach is statistically invalid, it is the favored method for identifying outliers in Ontario laboratory quality control protocols. DESIGN AND METHODS: Computer simulations are used to calculate the probability of a false positive result (classifying a valid observation as an outlier) when outlier criteria based on fixed multiples of the standard deviation are applied to samples containing no outliers. RESULTS: The estimated probability of a false positive result is tabulated over various sample sizes. Outlier criteria based on fixed multiples of the standard deviation are shown to be highly inefficient. CONCLUSIONS: This work presents arguments for discontinuing the widespread practice of using outlier criteria based on fixed multiples of the standard deviation to identify outliers in univariate samples.

Clinical Chemistry Tests↗

Sample to sample carryover: a source of analytical laboratory error and its relevance to integrated clinical chemistry/immunoassay systems.

BACKGROUND: Integrated systems that combine clinical chemistry and immunoassay analyzers are used routinely. Sample to sample carryover is an inherent risk and can cause erroneously high patient test results for immunoassays. IVD manufacturers and laboratories must be aware of this phenomenon and guard against it. METHODS: We used a sample carryover protocol that directs the clinical chemistry module to process samples with very high immunoassay analyte concentrations followed by samples with very low concentrations for the same analyte. Low concentration samples were then tested by the immunoassay module to determine if the clinical chemistry module caused primary sample tube to primary sample tube carryover of the immunoassay analyte. RESULTS: Sample carryover was assessed on the Abbott ci8200 for HBsAg, AFP, beta-hCG, and PSA. Observed HBsAg carryover met the design specification of <0.1 ppm. Carryover for the other analytes was <0.1 ppm or below the assay limit of detection. CONCLUSIONS: IVD manufacturers must design integrated systems to minimize primary specimen tube carryover and avoid analytical laboratory error that can impact patient safety. Carryover testing is difficult for clinical laboratories to perform in order to verify system performance. Laboratories must consider the potential for specimen carryover and its impact on results whether moving primary sample tubes between separate analyzers or using an integrated system.

Clinical Chemistry Tests↗