Titanium release from implants prepared with different surface roughness.

Abstract

OBJECTIVES: There may be a risk of greater ion release for surface-enlarged implants than conventionally turned components. The major aim of the present paper was to investigate whether a correlation exists between ion release and a surface roughness relevant for today's commercial implants. Other aims were to compare ion release after two insertion times and concentration in bone tissue as a function of distance from the implant surface. MATERIAL AND METHODS: Lactic acid aqueous solution (pH=2.3) and phosphate-buffered saline were used for the in vitro investigation. For the in vivo investigation, synchrotron radiation X-ray fluorescence (SRXRF) spectroscopy and secondary ion mass spectroscopy (SIMS) were performed 12 weeks and 1 year after implantation in rabbit tibiae. RESULTS: The average height deviation (S(a)) was 0.7, 1.27, 1.43 and 2.21 microm, respectively, for the four surfaces investigated. No difference in ion release was found in vitro. In vivo, SRXRF demonstrated slightly higher values for the roughest surface up to a distance of 400 microm from the implant surface; thereafter no difference was found. SIMS demonstrated no difference in ion release for the roughest and smoothest surfaces, but slightly more titanium in bone tissue after 1 year than after 12 weeks. Titanium rapidly decreased with distance from the implant surface. CONCLUSION: At a level relevant for commercial oral implants, no correlation was found between increasing roughness and ion release, neither in vitro nor in vivo.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ann Wennerberg, Ari Ide-Ektessabi, Shino Hatkamata, Takashi Sawase, Carina Johansson, Tomas Albrektsson, Anna Martinelli, Ulf Södervall, Hans Odelius. 2004. Titanium release from implants prepared with different surface roughness.. https://doi.org/10.1111/j.1600-0501.2004.01053.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The impact of modifying alumina air abrasion parameters on the fracture strength of a porcelain laminate restorative material.

OBJECTIVES: The modification of the "fit" surface of porcelain laminate veneer restorations in order to improve adhesion prior to cementation is often indiscriminate. As a consequence, the surface flaw distribution which is implicated in the probability of failure of the restoration is likely to be dramatically modified. The purpose of the current study was to examine the impact of different air abrasion surface treatments on the bi-axial flexure strength and surface roughness of a porcelain restorative material. METHODS: Sets of 30 Vitadur-Alpha dentin porcelain discs (15 mm diameter, 0.9 mm thickness) were alumina abraded with three different grades of alumina particle (25, 50 and 110 microm), utilizing two different air stream pressures (35 and 70 psi) and two distinct angles of incidence of particle delivery (45 degrees and 90 degrees ). Mean bi-axial flexure strengths, standard deviations, the associated Weibull moduli (m) and characteristic stress were determined using bi-axial flexure (ball on ring). RESULTS: A univariate general linear analysis of means revealed a significant difference between the mean bi-axial flexure strength values of the control group and those of groups subjected to alumina particle air abrasion. Further significance (P<0.05) was discovered with the impact of alumina particle size and the interaction between particle size and angle of incidence of particle delivery. The reliability of the fracture strength data generally improved when 50 microm alumina particles were used whereas discontinuities existed at lower strength values when 25 and 110 microm alumina particles were employed. CONCLUSIONS: Alumina particle air abrasion has a significant degradative effect on the bi-axial flexure strength of the porcelain disc-shaped specimens. Variation of alumina size, delivery pressure and angle of particle delivery all impacted on the degree of strength reduction and the shape of the survival probability distributions. It is suggested that alumina particle air abrasion acts to remove/modify the initial flaw distribution replacing it with flaws of differing geometry and stability. The premature failure of porcelain laminate restorations may be markedly influenced by alumina particle air abrasion depending upon the size and distribution of the crystalline phase present in different dentine porcelains materials used in construction of the restoration.

Air Abrasion, Dental↗

Effects of surface conditioning on bond strength of metal brackets to all-ceramic surfaces.

The aim of this study was to determine the effectiveness of bonding brackets to ceramic restorations. Sixty feldspathic and 60 lithium disilicate ceramic specimens were randomly divided into six groups. Shear bond strength (SBS) and bond failure types were examined with six surface-conditioning methods: silane application to glazed surface, air particle abrasion (APA) with 25- and 50-microm aluminium trioxide (Al(2)O(3)), etching with 9.6 per cent hydrofluoric acid (HFA), and roughening with 40- and 63-microm diamond burs. Silane was applied to all roughened surfaces. Metal brackets were bonded with light cure composite, then stored in distilled water for 1 week and thermocycled (x500 at 5-55 degrees C for 30 seconds). The ceramic surfaces were examined with a stereomicroscope at a magnification of x10 to determine the amount of composite resin remaining using the adhesive remnant index. The lowest SBS values were obtained with HFA for feldspathic (5.39 MPa) and lithium disilicate (11.11 MPa) ceramics; these values were significantly different from those of the other groups. The highest SBS values were found with 63-microm diamond burs for feldspathic (26.38 MPa) and lithium disilicate (28.20 MPa) ceramics, and were not significantly different from 40-microm diamond burs for feldspathic and lithium disilicate ceramics (26.04 and 24.26 MPa, respectively). Roughening with 25- and 50-microm Al(2)O(3) particles showed modest SBS for lithium disilicate (22.60 and 26.15 MPa, respectively) and for feldspathic ceramics (17.90 and 14.66 MPa, respectively). Adhesive failures between the ceramic and composite resin were noted in all groups. Damage to the porcelain surfaces was not observed. The SBS values were above the optimal range, except for feldspathic ceramic treated with HFA and silane. With all surface-conditioning methods, lithium disilicate ceramic displayed higher SBS than feldspathic ceramic.

Air Abrasion, Dental↗

Pain perception in children during caries removal with the Vector system: a pilot study.

AIM: A pilot study to compare pain perception during caries treatment in children by means of: the Vector system versus a mechanical method. STUDY DESIGN AND METHODS: A population of 31 children, aged 7-11 years, with a positive attitude towards dental treatment was recruited. Every child had two permanent molar teeth treated, one using the Vector system (piezo-driven ultrasonic device) and the other using conventional method (dental bur). Corah, Hochman and the visual scale (Facial Expression Scale) were applied to evaluate anxiety and pain perception. RESULTS: Treatment with the Vector system required significantly longer time 31.1 versus 4.7 mins for the conventional method. With the Vector system 54.8% of children and with conventional method 29.0% felt no pain. Girls admitted to feeling more pain than boys (verbal scale p < 0.018, visual scale p < 0.072). A high statistical correlation between verbal and visual scales was confirmed (r = 0.821; p < 0.001 and a greater level of pain was found using conventional method. CONCLUSIONS: The Vector system is useful in treating caries in children, because it minimizes the negative attitudes to pain but takes significantly longer to use.

Air Abrasion, Dental↗